Read the Unit Before the Number

If a handover sheet says “TDS 240,” ask what instrument or lab produced it. On a pocket meter, the EC setting reports electrical conductivity, usually in µS/cm. The TDS setting on that same meter typically estimates dissolved solids from conductivity. A laboratory TDS result can also appear in mg/L, so the unit alone won’t tell you which method was used.

The ppm label means parts per million. If it is expressed by mass, 1 ppm equals 1 mg/kg. In dilute fresh water, a liter weighs close to a kilogram, so a mass-based ppm value is numerically close to mg/L. An EC value needs a separate calculation to get an estimate of dissolved solids.

[1] [2] [3]

ConductivityµS/cm
An electrical measurement. Specific conductance reports conductivity at a stated reference temperature, commonly 25 °C.
TDSmg/L
Total dissolved solids: an aggregate result whose meaning depends on the analytical or estimation method.
ppm1 mg/kg
One part per million by mass equals 1 mg/kg. In dilute fresh water, mg/L is approximately equivalent because one liter has a mass close to one kilogram.

One Conductivity Reading Can Give Two TDS Estimates

The conductivity in the example below stays at 400 µS/cm. With the factor set to 0.55, the meter calculation gives 220 mg/L. At 0.75, it gives 300 mg/L. These settings illustrate the calculation. To compare actual results, check which factor or conversion scale each instrument uses. Waters with different mixes of dissolved ions can respond differently.

Check the temperature basis too. A report of 25 °C specific conductance refers to a value at a common reference temperature. The sample may have been colder or warmer, with the instrument converting its reading to that reference. Save the actual sample temperature and the compensation setting so you can repeat the check.

[1] [3] [4]

Same Input, Different Factor

Conductivity at the stated reference: 400 µS/cm

Conversion Factor 0.55
400 × 0.55 = 220 mg/L
Estimated TDS
Conversion Factor 0.75
400 × 0.75 = 300 mg/L
Estimated TDS

Arithmetic examples, not measured samples or recommended settings. For this numeric conversion, conductivity is in µS/cm and estimated TDS is in mg/L. Use a factor appropriate to the instrument and water being evaluated.

Two River Samples, Two Test Methods

The City of Rio Vista’s quarterly monitoring record listed two Sacramento River sampling points for April 9, 2024. The attached laboratory report gives RSW-002 as 194 umhos/cm and 93.7 mg/L TDS. RSW-003 shows 192 umhos/cm and 104 mg/L TDS. The quarterly summary labels the conductivity results at 25 °C, abbreviates the unit to “umhos,” and displays the first TDS result as 94 mg/L. Those TDS results come from the 180 °C residue method.

The conductivity numbers are close. In these records the point with the lower reported conductivity has the higher laboratory TDS. When checking the result from a restaurant tap, trace the location, date and test methods in the same way.

With a gravimetric method, the lab filters the sample, evaporates the filtrate and weighs the dried residue under the stated procedure. Other reports may identify TDS as a sum of individually measured constituents. If you need a value for acceptance, ask for the agreed method and the matching point of collection.

[5] [6] [1] [3]

Four Results That Answer Different Questions
ResultHow It Is ObtainedWhat It Describes
Conductivity · µS/cmElectrical response of a probe; record the temperature basis.The combined electrical behavior of the dissolved ions.
Estimated TDS · mg/L or ppmConductivity converted with an assumed factor.An estimate linked to that conversion.
Gravimetric TDS · mg/LFilter, evaporate, dry and weigh according to the stated method.Residue determined by that laboratory procedure.
Hardness · mg/L as CaCO₃A separate hardness determination.Primarily the contribution of calcium and magnesium, expressed on a calcium-carbonate basis.
A hand holds a portable water meter beside a water outlet, with its probe in a glass
A handheld meter in use beside a water dispenser. The photograph illustrates the measurement setup; it does not provide a laboratory result or the values used in this article’s worked example.

Decide Which Test Answers the Question

Say the complaint is scale on a heater. A higher TDS display can prompt a check. Ask for hardness when you are investigating deposits. If the question is a named chemical or a microbiological concern, order the relevant test through the responsible water supplier or laboratory.

If you are checking against a published benchmark, read the purpose of the figure. For instance, 500 mg/L is U.S. EPA’s federal secondary TDS guideline for drinking water. A project specification can ask for a particular analysis at the outlet.

Decide when to measure hardness, alkalinity or pH

[9] [8] [7] [12]

Write Down Enough to Repeat the Reading

For a Bestware installation handover, a useful field comparison would start at fixed points before and after the installed treatment stage. Record the tap or sample point, date, time and draw conditions. Use the same calibrated instrument and EC mode, wait for a stable result, and note the sample temperature plus the reference and compensation settings. If you record an estimated TDS too, keep the factor or conversion scale beside it.

Repeat a surprising reading at the same point with the same procedure. If the change persists, share the two records with whoever manages the supply. To compare with laboratory TDS, coordinate collection at the same point and time with the lab, and confirm the required method and sample handling first.

Match the water supplier’s report to your tap and reporting period

[1] [10] [11]

A Useful Measurement Record

Sample
Point of collection, date and time; identify any treatment stage.
Electrical Result
Conductivity, unit, sample temperature and reference temperature.
Conversion
TDS estimate, conversion factor and compensation setting.
Instrument
Instrument model or ID and calibration check; attach relevant laboratory results.

Sources for This Edition

  1. U.S. Geological Survey · National Field Manual, Chapter A6.3: Specific Conductance · 2019, §1.1 (printed pp. 2–3), §§3.3, 4.1.2 and 6.0. Effects of temperature and ions, the 25 °C reporting reference, calibration, stable readings and sample temperature.
  2. U.S. EPA · Test Methods: Data Reporting Questions · Reporting Forms, Qualifier Flags, and Reporting Units, question on ppm versus mg/kg. By mass 1 ppm = 1 mg/kg. The numerical mg/L approximation for dilute water depends on density.
  3. U.S. Geological Survey · Scientific Investigations Report 2017–5006 · Printed p. 45 (PDF p. 63), Methods. Multiprobe estimates TDS from conductivity. Laboratory results can use evaporation residue or a sum of measured constituents. Conversion depends on the water.
  4. Bestware Wiki · Illustrative Conductivity Conversion · Fixed 400 µS/cm input times factors 0.55 and 0.75 gives estimates of 220 and 300 mg/L. The factors are used only for the example.
  5. California State Water Resources Control Board · Rio Vista City, Beach WWTF, Q2 2024 · Monitoring Locations and Data Summary–Analytical. April 9, 2024, Sacramento River RSW-002 and RSW-003. At 25 °C under 2510 B: 194 and 192, reported as “umhos”. Under 2540 C at 180 °C: 94 and 104 mg/L TDS.
  6. Fruit Growers Laboratory · April 9, 2024 Receiving Water Monitoring Results (CIWQS PDF attachment) · PDF pp. 2 and 4, Sample Results, Wet Chemistry. RSW-002: specific conductance 194 umhos/cm and TDS 93.7 mg/L. RSW-003: 192 umhos/cm and 104 mg/L. TDS method SM 2540 C in both. The quarterly electronic report displays 94 and 104 mg/L.
  7. World Health Organization · Total Dissolved Solids, Chemical Fact Sheet · 18 May 2022, linked fact sheet, printed pp. 470–471. WHO proposes no health-based guideline value for TDS as an aggregate.
  8. U.S. EPA · Secondary Drinking Water Standards · What are Secondary Standards? and the standards table. U.S. federal secondary TDS guidance is 500 mg/L. States may choose to make secondary standards enforceable.
  9. U.S. Geological Survey · Selected Constituents and Their Importance · Hardness of Water entry. Hardness chiefly reflects dissolved calcium and magnesium and relates to scale deposits.
  10. Bestware Wiki · Illustrative Installation Handoff · Example with fixed points before and after installed treatment. Keep meter mode, repeat conditions and sample details. No Bestware lab or model performance result.
  11. Bestware Wiki · Local Water Quality Reports · Match the report to the service address and find the method for the result.
  12. Bestware Wiki · Hardness, Alkalinity and pH · Separate scale and mineral questions into the measurements needed before buying treatment.
  1. World Health Organization · Total Dissolved Solids, Chemical Fact Sheet · 18 May 2022, linked fact sheet, printed pp. 470–471. WHO proposes no health-based guideline value for TDS as an aggregate.
  2. U.S. EPA · Secondary Drinking Water Standards · What are Secondary Standards? and the standards table. U.S. federal secondary TDS guidance is 500 mg/L. States may choose to make secondary standards enforceable.

Continue With These Decisions