Put the Pan in the Sink Before You Choose the Faucet

Start with the widest pan the closing crew brings to the sink. With the shelves and doors in their working positions, check if the pan tilts into the bowl, whether the gun can follow its rim, and where the operator’s elbow and the hose go. Measure up from the finished deck, then look underneath for the connections and room to work on them.

Suppose the truck has an existing 22 mm opening and 700 mm to the underside of a shelf. Bestware’s AS106C Mini is cold-only and uses one 21–23 mm hole. The drawing puts the top at 682 mm, leaving 18 mm on paper in that layout. The drawing also limits the deck to 25 mm thick. Run the actual movement before accepting it. If the fixture needs hot and cold feeds, the single-hole AA106C is 672 mm high but calls for a 32–35 mm hole. The 728 mm AD106C takes two holes, 101.6–203.2 mm apart, and would exceed the sample shelf height.

[1] [2] [3] [5]

Run It on the Supply the Crew Will Use

Record whether the shift uses the onboard pump and tank, an approved site connection, or both as distinct setups. Keep the sources on their approved connections and have the installer identify the shutoff and required backflow protection before the trial. On the tank run, record the usable water level and heater setting. Ask the installer to note the inlet pressure while the gun is flowing. If staff normally draw water somewhere else at the same time, repeat with that draw in use. Compare trigger response, flow interruptions and where splash lands.

The FDA Food Code 2026 is a US model. It addresses peak water demand, pressure and mobile water and waste tanks. For example, §5-401.11 calls for a mobile food establishment’s sewage holding tank to be 15% larger than its water supply tank. It also calls for flushing and sanitizing a mobile tank, pump and hoses after installation, repair or modification, and protecting the system from backflow. Check the adopted requirements with the operating jurisdiction. Los Angeles County’s mobile plan check treats the approved operation, sinks and water systems as a package. The gun can help with pre-rinsing. The planned warewashing process still needs its own review.

[5] [6] [7]

Time the Water and Time the Job

Catch water for a fixed interval with the fitted gun in one mode. In a worked example, 1.2 L collected in 20 seconds comes to 3.6 L/min. Six equal 20-second spray draws at that rate would use 7.2 L for spraying. Actual use also depends on how long the trigger stays open, and filling a sink, handwashing and other draws need their own water allowance.

Then rinse the same pan under each approved supply setup. Record the time the trigger was open, total task time and how much water the task took. Note whether water spills out, the pump cycles during use or the bowl drains slowly. Try the add-on swing spout separately. Its aerator rating describes that outlet, so compare it to its own measured result.

[4] [6] [11]

Sign for the Parts and Setup That Arrived

Put the body, exact model suffix, hose and spray valve on the order. For AS106C, AA106C and AD106C the product pages show 925 mm, and each model flyer shows 600 mm. Confirm the supplied hose code and dimension on the order drawing, then check the delivered reach in the truck. The product page also distinguishes the standard BWSG-SSE dual-function gun from the optional BWSG-SSJ. Put the one you tested on the handover sheet.

IAPMO file 12528 lists an AS1_ family for deck-mounted pre-rinse fittings. IAPMO file 12530 is the separate lead-content listing under NSF/ANSI/CAN 372-2024 and also shows AS1_. Confirm the exact suffix and ordered assembly against each listing required by the project. Keep the fitted drawing, water and waste readings, and the vehicle installer’s transport restraint check with the test. A change in pump, hose or mounting calls for a repeat of the affected checks.

Use the spray valve guide for the gun’s own checks

[1] [4] [5] [10] [11] [12] [13] [14]

Sources for This Edition

  1. Bestware AS106C · American Mini, single-hole cold-water model · Page 1, deck drawing and specification table. 682 mm above the deck, Ø21–23 mm mounting opening, max 25 mm deck thickness, cold-water only. The flyer says 600 mm for the spray hose.
  2. Bestware AA106C · American Mini, single-hole hot-and-cold model · Page 1. 672 mm above the deck, Ø32–35 mm single opening and 41 mm max deck thickness. Hot and cold water, with a 600 mm hose listed in the flyer. This flyer specifies a 600 mm hose.
  3. Bestware AD106C · American Mini, two-hole hot-and-cold model · Page 1. 728 mm above the deck, two Ø21–23 mm openings, 101.6–203.2 mm between centers, 25 mm max deck thickness. The flyer lists a 600 mm hose. This flyer specifies a 600 mm hose.
  4. Bestware AS106C · Current product specifications and spray curves · Hose field says 925 mm, differing from the manufacturer's 600 mm flyer. Spray Valve fields identify standard BWSG-SSE and optional BWSG-SSJ. The separately listed aerators belong to the add-on swing spout.
  5. Bestware American Mini pre-rinse faucet installation manual · PDF pages 5–9. Assembly and deck/wall installations for the specified models, including fitting access and supply configurations. Vehicle transport restraint is a separate approval.
  6. FDA Food Code 2026 · Mobile water, wastewater and warewashing · US model code. §§5-103.11–.12 (PDF 148) cover demand and pressure, §§5-302 to 5-304 (PDF 153–155) mobile supply and tanks, §5-401.11 (PDF 155) wastewater tank sizing and drainage, §4-301.12 (PDF 126) manual warewashing facilities. Check local adoption. §§5-304.11 and 5-304.12 cover flushing and sanitizing, and protection against backflow.
  7. Los Angeles County · Mobile Food Facility Plan Check Guideline · County plan review guidance on the proposed operation, sinks, potable and waste tanks, and hot water. Requirements depend on the facility category and menu.
  8. Reglamento (CE) 852/2004 · Anexo II, capítulo III · Annex II, Chapter III, paragraphs 2(c), (e) and (f). Mobile premises, suitable utensil cleaning and disinfection where necessary, adequate hot and/or cold potable water and hygienic waste handling.
  9. 上海市流动餐车管理办法 · 第 11、14 条 · Articles 11(6) and 14. Shanghai requires cleaning and disinfection facilities appropriate to the type and quantity of food, with local operating and waste management requirements.
  10. IAPMO listing 12528 · Scoped plumbing fixture fittings · ASME A112.18.1-2024 / CSA B125.1-24, with family entry AS1_. Confirm the precise suffix and supplied body, hose and spray valve combination against the current model schedule. Public model row AS1_. The three Mini suffixes were left pending.
  11. Bestware · Pre-rinse spray valve acceptance · Companion article covering flow, hand operation, useful spray area and test records for the spray valve itself.
  12. Bestware AA106C · Product specifications · Model-specific Hose Size field on the manufacturer product page lists 925 mm.
  13. Bestware AD106C · Product specifications · Model-specific Hose Size field on the manufacturer product page lists 925 mm.
  14. IAPMO R&T file 12530 · Lead content · NSF/ANSI/CAN 372-2024. The public list shows AS1_ for deck-mounted pre-rinse fittings. Exact Mini codes and ordered spray configurations are pending.