Try the Sink With the Cook Line Set Up for Service
Put the prep cart and waste bin back where they normally stand. Ask someone who works the line to walk up to the basin, start the water with a knee, wash and reach for the soap and drying supplies. Watch whether they can stay steady and keep both hands over the bowl. Have another regular user try it, especially if they stand or approach the basin differently.
A Maricopa County inspection recorded cables and crates blocking a handwashing sink beside a cook line. The person in charge moved them during the visit. When you walk the route at handover, check where a bin, crate or swinging door could get in the way during service. If the point must meet accessibility requirements, have the applicable floor space, knee and toe space, and controls checked against the installed layout. A standing demonstration covers the standing task.
Put the Basin and Valve on the Same Order
The Bestware SSKNBS is a wall-mounted basin with an SUS304 body and an overall product size of 500 × 400 × 395 mm. Use that to check what fits against the wall. Set and check the rim height and the position of the knee plate on the installed drawing. The trap, pipework, guards and any adjacent doors also need room once the unit is fitted.
The catalogue shows two valve options for this basin. With SSKNV-A, water runs while the knee plate is held and stops on release. With BWFVATF, one press starts a timed run. The catalogue lists factory presets of 6 or 16 seconds and an adjustable range of 6–16 seconds. Ask the supplier to name the valve and the delivered preset on the order, then check the assembly you receive.
Verify the Supply and the Outlet Temperature
The standard SSKNBS is supplied for cold water. For mixed water, Bestware’s 2026 V1.6 catalogue calls the optional thermostatic mixer SSKNV-B. An older, discontinued listing used that code for a 90° knee valve. Confirm the actual mixer and both connections on the quotation drawing and received part label before closing the item. At handover, measure the temperature at the outlet with the agreed supply conditions.
For a US job, establish what the local jurisdiction has adopted. In the FDA Food Code 2026 model, §5-202.12(A) calls for a sink capable of delivering at least 85 °F (29.4 °C) through a mixing valve or combination faucet. The adopted requirement or project specification is what the installer and operator enter on the acceptance sheet.
Check One Activation, Then the Full Wash
On the timed version, use the control as specified and record the seconds from the first water to shutoff after one activation. Record any interruption or second press. If the project applies the FDA model clause for self-closing, slow-closing or metering faucets, §5-202.12(C) calls for at least 15 seconds of flow without reactivation. Even a delivered 16-second preset needs a timed check in the fitted unit. Confirm how the local reviewer treats the hold-to-flow option before accepting it for a site with a specified faucet category.
On the hold-to-flow version, observe the water while the user holds the plate and check that it stops when released. Run the full washing routine with soap and drying supplies on either version. The 20 seconds in FDA model §2-301.12 refer to the employee’s hand-cleaning procedure. Record the procedure and the valve cycle as separate checks.
Sign for the Assembly and Location You Tested
Put the basin, valve, mixer if fitted, mounting revision and exact location on the record. Keep the measured outlet temperature and the timed or hold-to-flow result next to the conditions. Check the fitted supply and drain for leaks, verify that the mounting stays secure, and see that the staff can reach soap and a way to dry their hands. The handwashing point stays clear and available for that job during service.
For a site that applies the FDA model rule to the timed faucet, specify SSKNBS with BWFVATF at the catalogue’s 16-second preset and identify the approved mixer assembly if the project needs mixed water. Have the installer confirm the connections. Close acceptance only after the installed continuous flow time, outlet temperature and on-site checks meet the agreed criteria. Put the name and due date beside any open item, and retest after changes to the valve, supply or mounting.
Sources for This Edition
- Bestware SSKNBS · Wall Mount Knee-Operated Wash Sink · Specifications, Water Flow Mode and Temperature Control. Wall-mounted SUS304 body, 500 × 400 × 395 mm overall product size, default cold-water supply and optional thermostatic mixing.
- Bestware Wash Sink Series · SSKNBS Drawings and Valve Options · PDF page 3, printed page 01. SSKNV-A instant flow, BWFVATF delayed shutoff, optional SSKNV-B thermostatic mixing. Delayed-flow factory presets of 6 or 16 seconds and an adjustable range of 6–16 seconds.
- FDA Food Code 2026 · §5-202.12 Handwashing Sink Installation · PDF pages 149–150, paragraphs (A) and (C). At least 29.4 °C (85 °F) through a mixing valve or combination faucet, and at least 15 seconds without reactivation for the specified faucet categories. US model provisions subject to local adoption.
- FDA Food Code 2026 · Handwashing Procedure, Location and Supplies · §2-301.12 (PDF page 67), §§5-204.11 and 5-205.11 (page 151) and §§6-301.11, .12 and .14 (page 166). Hand-cleaning procedure, convenient location, access, dedicated use, supplies and signage.
- Maricopa County Environmental Services · Public Inspection INSP-037003-2024 · Violation No. 10. Cables and crates blocked a cook-line handwashing sink. The responsible person moved them during the inspection. No faucet model is identified.
- U.S. Access Board · Guide to Lavatories and Sinks · Required Compliance, Clear Floor Space and Faucets and Operable Parts. Check scope and the installed conditions separately when accessibility applies.
- México · NOM-251-SSA1-2009, Prácticas de higiene · Section 7.2.2, handwashing and sanitizing station and supplies in the food preparation area of food or beverage service establishments.
- GB 31654—2021 · 食品安全国家标准 餐饮服务通用卫生规范 · Sections 4.4.1–4.4.5, PDF page 4, printed page 3. Non-hand-operated taps and recommended warm water in the specified dedicated zones.
- Bestware · Metering Faucet Cycle Acceptance · Cycle timing, actual delivered volume and reset behavior after valve replacement or adjustment.
- Bestware Catalogue 2026 V1.6 · SSKNBS and optional mixer · PDF page 58, printed page 99. The current assembly diagram identifies SSKNV-B as the optional thermostatic mixer for both valve variants.
- Bestware legacy SSKNV-B product page · No longer available · Retired page, Product Description. The same code names a 90° self-closing knee valve there. A thermostatic mixer is a separate add-on on that retired listing.
Continue With These Decisions
- How to Test a Sensor Faucet in the Installed Basin
Use the same fitted basin to compare a sensor faucet if the site needs another hands-free control.
- Replacing a Commercial Tap? Measure the Existing Counter First
When reusing an existing station, verify its mounting, connections and service access.