What Was at Booth 4700
Bestware displayed a four-option water dispenser, commercial pre-rinse faucets, a sensor faucet and a hose reel at RC Show 2026. The show ran March 8–10 at The International Centre in Mississauga, Ontario. Restaurants Canada’s exhibitor map places Bestware Hardware Production Co., Ltd. at booth 4700. Bestware’s March 11 report identifies Hall 4 and lists what was on display.
The show photo catches people standing along the counter, with faucets above and equipment visible through the lower display. Bestware’s report describes four water options on the dispenser: chilled still, hot, sparkling and room-temperature. It also lists American- and European-style pre-rinse assemblies. Those are useful starting points for a conversation with a supplier. The kitchen drawing tells you which questions to ask next.
Put the Bar and the Dish Station on the Same Clock
Imagine a restaurant where 48 orders for 250 mL of sparkling water land inside 12 minutes. The bar needs 12 L in that window, which averages 1 L/min. If the tickets arrive in bunches, the person filling drinks can face several back-to-back pours. Write down the totals in the busiest few minutes and the service time you can give to each round. That is the load to send with a dispenser quote.
Then give the rinse station the same clock. If a worker clearing plates starts a new rack at the same time, the bar and the sink may draw from a shared branch. Ask the installer to read the water pressure during a beverage fill, then repeat the same fill with the rinse station in use. Record the serving size, how long the burst lasts and what happens to the last glasses in the sequence. The comparison tells you where the slowdown sits before you change the equipment list.
Calculate the water required in your restaurant’s peak window
Measure the Existing Sink Before Replacing a Pre-Rinse Assembly
Start with the opening in the deck and the water supply below it. For example, the current Bestware AS112 catalog specifies a single cold feed, a single-hole deck mount and a 21–23 mm opening. If the existing hole measures 22 mm, it fits the listed diameter range. Supply, clearance under the deck and the spray head’s reach over the sink still have their own checks.
For the rinse test, hand the operator the pan they actually struggle to clean and run the job at the sink’s normal working pressure. Time the trigger, and note where the spray lands and whether water jumps back over the edge. A US EPA field study that followed work at ten kitchens in 2010 found that spray valves with the same laboratory cleanability time could receive different satisfaction scores. Operators’ feedback included spray pattern and perceived spray force. That is a good reason to keep the worker’s real task in the acceptance test.
Use the pre-rinse station acceptance checks at the existing sink
Walk the Route the Hose Will Take
The sensor faucet and the hose reel cover two other kinds of work. Give the sensor faucet its intended basin and check activation at the places users actually hold their hands, shutoff when they pull away and access to the power supply and shutoff valve. Test from the side too if a cabinet, wall or neighboring fixture changes the way users reach the basin.
For the reel, mark the intended wall location, the far corner to be washed and the path between them. Pull a hose around the real legs, doors and carts along that route. Check where it rests when parked and whether the operator can return it without crossing an active work area. Add those two marked-up locations to the beverage and sink requirements. Now the parties quoting the same job can work from the same plan.
Sources for This Edition
- Restaurants Canada · RC Show 2026 Post-event Report · March 16, 2026. Opening paragraphs identify Restaurants Canada, The International Centre in Mississauga, Ontario, and the March 8–10 dates.
- RC Show 2026 · Event Map and Exhibitor Listing · The listing shows BESTWARE HARDWARE PRODUCTION CO., LTD. at booth 4700.
- Bestware Stainless · RC Show 2026 Booth Report · March 11, 2026. Opening identifies Hall 4 and booth 4700. The numbered product list identifies the four categories and the four water options on the dispenser.
- Bestware Stainless · Photograph of Its RC Show Counter · First of the two booth photographs at the end of the March 11 report. Visitors are visible alongside faucets and the lower product display.
- Worked Example · A Restaurant’s Coinciding Service Loads · Hypothetical planning window. Forty-eight orders of 250 mL in 12 minutes require 12 L total, or 1 L/min on average across the interval. This is buyer demand.
- Bestware Stainless · AS112 Product Specifications · Current catalog example. Specification table: single cold-water supply, single-hole deck mount, Φ21–23 mm opening. Separate from the show report.
- US EPA WaterSense · Pre-Rinse Spray Valves Field Study Report · March 31, 2011. Executive Summary, Figure 7 in §6.4.3 and Table 8 in §6.4.4. Field monitoring in ten commercial and institutional kitchens in the Boston and Washington, DC, areas in 2010.
- Bestware · Restaurant Water Capacity Calculator · Turn cups, fill volume and the peak window into a beverage-side demand estimate.
- Bestware Wiki · Accepting Pre-rinse Spray Valves · Check mounting, supply, spray behavior and the actual dishwashing task when accepting a pre-rinse station.
Continue With These Decisions
- Restaurant Sparkling Water Capacity Calculator
Calculate the water required in your restaurant’s peak window
- How to Test a Commercial Pre-Rinse Spray Valve Before You Accept It
Use the pre-rinse station acceptance checks at the existing sink