Systems / G1DS-110
Integrated undercounter

G1DS-110

Integrated 4-function water system

Chilled · Sparkling · Hot · Ambient. Integrated undercounter. Without RO.

G1DS-110 — Integrated undercounter

PRODUCT FILM

See the System in Action

An overview of the system and its operation.

Suggest a Product Improvement
Technical specifications

Model Specifications

Capacities apply under the manufacturer’s published conditions. Instantaneous flow is different from sustained hourly capacity.

Water optionsChilled · Sparkling · Hot · Ambient
Equipment layoutIntegrated undercounter
FiltrationWithout RO
Tap and Drip Tray Dimensions (W x D x H)158x223x332 mm
Tap Body MaterialPlasma mirror-polished SUS304 stainless steel (unplated)
Tap Animated Display Screen1.5-inch OLED HD display with smart rotary control
Tap Communication InterfaceShared with the main unit
Chilling Unit Supply Voltage110 V/60Hz or 220 V/50Hz
Chilling Unit Water Pressure Range0.15 MPa~0.6 MPa
Chilling Capacity20 L/h, = 100 cups/h (200 ml/cup)
Chilling Unit Adjustable Temperature Range0℃~8℃
Chilling Unit Inlet/Outlet Water Pipe Connection¼" PE
Chilling Unit UV SterilizationExternal
Sparkling CapacityMax 1.5 L/min
Sparkling Water Concentration3 Vol
Chilling Unit CO2 CylinderReplaced by the customer
Chilling Unit CO2 Operating Pressure0.35-0.4 MPa (audible alert below 0.1 MPa)
Chilling Unit CO2 Intake Pipe¼" PE
Heating Power Rating2100 W
Heating CapacitySingle continuous draw (≈3 L) at 95°C+; 15 L/h, =100 cups/h (150 ml/cup)
Heating Unit Adjustable Temperature Range45℃~98℃
Heating Unit High-pressure Relief PortYes
Heating Unit Inlet/Outlet Water Pipe Connection¼" PE
Heating Unit Dry-Fire ProtectionYes
Heating Unit Anti-scaldYes
Hole Size for TapΦ32~35 mm
Drip Tray Hole Size for TapHole Size Φ130 mm,3×Φ8 mm
Maximum Countertop Thickness for Tap Installation≤40 mm (custom options for thicker countertops)
Minimum Base Cabinet Dimensions (W x D x H)425x500x630 mm
All-in-One Unit Dimensions (W x D x H)355 × 464 × 438 mm

Confirm order voltage and the complete installation footprint, including maintenance access and optional modules.

Sizing the G1DS-110 for Service

Use the rated chilling capacity in the specification table for an hourly planning comparison. The maximum sparkling flow describes how fast water can leave the tap. Ask for a timed draw and recovery check at your expected inlet and room temperatures before specifying the model for a busy service.

Check the equipment and cabinet dimensions in the table, then allow for ventilation, filter changes and access to the CO₂ cylinder. Use the installation manual for the layout. Ask for the nameplate and any applicable listing for the complete model and voltage being quoted.

Compare restaurant configurations

Calculate peak water demand

Installation

Installation Planning

  • Use drinking water that meets the equipment requirements.
  • Check connections, supply voltage and maintenance access.
  • Allow for filtration modules and the CO₂ cylinder where applicable.

Resources

Product Documents

View or download the documentation for this model and the product range.

PDF

Installation & User Manual

G1DS-110 / G1DS-1010

Installation, operation and maintenance.

English2026 V1.114.5 MB

PDF

Product Catalog

Sparkling Water Range

Systems, configurations and range specifications.

English2026 V1.611.7 MB

Need another document? Contact our team

Suggest a Product Improvement

Specifications for Planning

Manufacturer rating

Rated cooling capacity
20 L/h

Published for chilling. The model summary places a water temperature of 10 °C or below beside this rating. Inlet temperature and a timed draw protocol are needed to compare it with an installation.

Manufacturer document

Maximum sparkling-water flow
1.5 L/min

The manufacturer rates this peak flow at the sparkling outlet. It helps compare the speed of a pour. Ask for a separate timed test for repeated service.

Manufacturer document

Sustained sparkling-water output
Not yet verified by a service test

For a restaurant trial, record inlet and room temperatures, the serving interval, and the volume that still meets the agreed temperature and carbonation targets.

Manufacturer document

Recovery after peak service
Not yet verified by a service test

Time how long it takes the unit to meet the agreed serving conditions again after a full run of pours.

Manufacturer document

Maximum thickness at the tap
40 mm

Measure the finished countertop at the tap opening.

Manufacturer document

Maximum thickness at the drip tray
36 mm

Measure the finished countertop separately at the drip tray.

Manufacturer document