## How to Keep the Right Water Filter Cartridges and CO₂ Cylinders in Stock

Set one reorder point for each cartridge and a separate one for beverage gas. Start with the parts actually installed, then put the next change date and the promised delivery date on the same calendar.

Revised 2026-11-24

A hand turns the handle of a removable cartridge on a water unit

On this page

[Start With What Is Installed](https://www.bestwaresoda.com/wiki/water-system-consumables/#section-1) [Map the Cartridge Change to a Purchase Date](https://www.bestwaresoda.com/wiki/water-system-consumables/#section-2) [Set the Order Point From Actual Demand](https://www.bestwaresoda.com/wiki/water-system-consumables/#section-3) [Give Beverage Gas Its Own Calendar](https://www.bestwaresoda.com/wiki/water-system-consumables/#section-4)

### Start With What Is Installed

A spare on the shelf counts when the technician can put it into the unit that needs it. If two locations run different treatment heads, give their cartridges separate stock lines even if the boxes look alike. Record which dispenser and filter head use each part, the manufacturer’s replacement catalog code, what the stage does and where sealed stock is kept. Keep an identification photo with the work order and have a receiver match the replacement before it goes on the shelf.

Where a treatment claim matters, check it against the exact system and replacement element in the certifier’s listing. Keep the treatment objective beside the part code. A cartridge for a taste or chlorine reduction job has its own selection criteria. The same head can also be sold for a different treatment claim. The installed combination is what the buyer needs to identify.

[\[4\]](https://www.bestwaresoda.com/wiki/water-system-consumables/#editorial-source-4) [\[5\]](https://www.bestwaresoda.com/wiki/water-system-consumables/#editorial-source-5)

### Map the Cartridge Change to a Purchase Date

The Bestware G1DS-1023 with its standalone reverse-osmosis unit offers a useful example of two stock lines. Bestware lists 12 months or 4,000 L for the PAC composite cartridge and 24 months or 8,000 L for the RO cartridge identified as 1000G in that configuration. Its FAQ tells operators to use the earlier of the calendar and volume limits. For a G1DS-123 order without that standalone RO unit, identify the actual upstream treatment separately. Request the orderable code for each cartridge on the delivered configuration.

Use cumulative volume since installation from the metering point and convention confirmed for the installed filter. Suppose an example PAC cartridge has been installed for eight months and the relevant reading is 3,100 L. Four recent representative weeks added 400 L. If that rate continues, the remaining 900 L will take about nine weeks, before the four calendar months still left. Use the earlier expected date to book the technician and buy the part in time. If the equipment or supplier calls for a change sooner, move the date forward. Record a meter reset when the instructions require it. For a meter that keeps running, save its new installation baseline.

[\[1\]](https://www.bestwaresoda.com/wiki/water-system-consumables/#editorial-source-1) [\[2\]](https://www.bestwaresoda.com/wiki/water-system-consumables/#editorial-source-2) [\[3\]](https://www.bestwaresoda.com/wiki/water-system-consumables/#editorial-source-3) [\[8\]](https://www.bestwaresoda.com/wiki/water-system-consumables/#editorial-source-8)

### Set the Order Point From Actual Demand

An operator with several of the same cartridges uses two every four weeks and typically waits six weeks for delivery. At that rate three will be needed before the next shipment. If the manager chooses one additional unit for variation, the reorder point is four usable cartridges when no delivery is already on track. Open orders count only if the confirmed arrival will cover the work. Stock marked for inspection or a different specification sits outside the available count. Check the quantity already allocated and whether a confirmed order will arrive before the specific work order needs it.

Write the date that the next technician needs a cartridge on the same sheet as the supplier’s promised arrival. If that date slips, call the supplier while you can still schedule the change and adjust the expected stock. Carry forward waste, return or emergency purchase against the original part line. The next count will show whether it was demand or a delivery delay that changed the result.

[\[5\]](https://www.bestwaresoda.com/wiki/water-system-consumables/#editorial-source-5) [\[7\]](https://www.bestwaresoda.com/wiki/water-system-consumables/#editorial-source-7)

### Give Beverage Gas Its Own Calendar

Plan CO₂ around eligible full cylinders at the site and the next exchange date. Use comparable fill sizes in the usage history. Record which service will take back the empties and who owns the order if the next delivery falls after a private event or a holiday. Agree usable spare capacity with the gas supplier and installer for the storage position at that address.

Leave the gas and cartridge lines separate in the weekly check. On each, keep the last issue date, usable quantity, next work date and confirmed supply contact. When a cartridge gets fitted, record the part, its batch where shown and the reading from which the interval restarts. The next shift can see the remaining stock and whether the outlet was actually released.

[Use the filter-change and return-to-service work order](https://www.bestwaresoda.com/wiki/cleaning-and-maintenance/)

[\[6\]](https://www.bestwaresoda.com/wiki/water-system-consumables/#editorial-source-6) [\[9\]](https://www.bestwaresoda.com/wiki/water-system-consumables/#editorial-source-9) [\[8\]](https://www.bestwaresoda.com/wiki/water-system-consumables/#editorial-source-8)

### Sources for This Edition

1. [Bestware G1DS-1023 specification](https://www.bestware-sparkling.com/Products/Commercial-Sparkling-Water-Dispensers/4-in-1/G1DS-1023) · Specifications, RO Filtration Unit entries for standalone configuration and the 1000G and PAC cartridge intervals. Public product-page-json from this same URL.
2. [Bestware G1DS-123 specification](https://www.bestware-sparkling.com/Products/Commercial-Sparkling-Water-Dispensers/4-in-1/G1DS-123) · Product name and configuration description, without standalone RO filtration.
3. [Bestware commercial dispenser FAQ](https://www.bestware-sparkling.com/sup_faq.html) · Consumables replacement question. Time or volume, whichever comes first for the two specified types. It gives no universal approved replacement part code.
4. [NSF — Drinking water filters and approved replacements](https://info.nsf.org/Certified/DWTU/Listings_leadreduction.asp) · Choosing the right replacement cartridge and how often they need to be changed. Specific to lead reduction listing, used as the model-and-cartridge claim method.
5. [Eastern Illinois University — Maintenance Repair Parts](https://www.eiu.edu/fpm/docs/Policies%20and%20Procedures%20for%20Maintenance%20Repair%20Parts.pdf#page=26) · Printed pages 24–25, CSPolicy #10, item-level reorder point, physical count and pre-order record. Procurement method only.
6. [EIGA Doc 67/20 — Carbon Dioxide Cylinders at Users’ Premises](https://www.eiga.eu/uploads/documents/DOC067.pdf#page=13) · Sections 12–15 for cylinder storage, use, refilling and maintenance. Site stocking schedule is an editorial operating example.
7. Illustrative cartridge ordering record · Two cartridges every four weeks for six weeks = three; one reserve gives four. No incoming order assumed. PAC example 900 L remaining at 100 L/week = nine weeks.
8. [Bestware — Filter change work order and return to service](https://www.bestwaresoda.com/wiki/cleaning-and-maintenance/) · Document replacement, meter reset, flush and the outlet reopening decision.
9. [Bestware — CO₂ supply and reorder planning](https://www.bestwaresoda.com/wiki/co2-cylinder-planning/) · Use the actual delivery address, weather or holiday schedule, and usable reserve before setting the gas reorder point.

### Continue With These Decisions

- [How to Run and Verify a Water Dispenser Maintenance Plan](https://www.bestwaresoda.com/wiki/cleaning-and-maintenance/)
  
  Record the exact installed cartridge and the release check after the change.
- [How to Plan CO₂ Cylinder Supply for a Sparkling Water Dispenser](https://www.bestwaresoda.com/wiki/co2-cylinder-planning/)
  
  Calculate gas reserve using the service address and actual exchange schedule.

### Continue Exploring

Related to this article

[Technology & Design 4 min read Updated 2026-11-25 How to Diagnose Flat Sparkling Water at the Tap Check a plain pour at the tap, during the rush and after the usual wait. Record when the fizz drops, the water temperature and any visible fault code. Read article](https://www.bestwaresoda.com/wiki/diagnosing-weak-carbonation/)

Related to this article

[Technology & Design 5 min read Updated 2026-11-25 When Should You Change a Commercial Water Filter? Use the fitted cartridge’s limits, a verified meter and service observations to set the next change. A Bestware PAC and RO example shows what to do when time and volume point to different dates. Read article](https://www.bestwaresoda.com/wiki/water-filter-replacement-criteria/)

Related to this article

[Drinks & Everyday Life 5 min read Updated 2026-11-25 Why the Water in Your Teapot Is Cooler Than the Display Shows Measure the same draw at the outlet and in the teapot. The pattern across your first, repeated and recovery draws tells you what to check next. Read article](https://www.bestwaresoda.com/wiki/check-temperature-at-the-brewing-point/)

Related to this article