# How to Verify a PFAS Filter Claim

Source: https://www.bestwaresoda.com/wiki/verifying-pfas-filter-claims/
Language: en-US

[Back to Water Wiki](https://www.bestwaresoda.com/wiki/)

Water & Science

## How to Verify a PFAS Filter Claim

Match the filter and replacement cartridge to the named compounds in a current listing. Then check what the test measured at the outlet.

Revised 2026-11-25

On this page

[Ask for the Outlet Number](https://www.bestwaresoda.com/wiki/verifying-pfas-filter-claims/#section-1) [Match the Model, Cartridge and Claim](https://www.bestwaresoda.com/wiki/verifying-pfas-filter-claims/#section-2) [Compare What the Test Actually Did](https://www.bestwaresoda.com/wiki/verifying-pfas-filter-claims/#section-3) [Keep the Certification Date and Site Target Separate](https://www.bestwaresoda.com/wiki/verifying-pfas-filter-claims/#section-4)

### Ask for the Outlet Number

Start with the water you need to treat. Write down whether the report names PFOA, PFOS or other members of the PFAS family. Keep the value and unit beside each name. For the proposed filter, ask for the test water concentration, the treated-water result and the compound or group that number covers. A label that gives only the percentage leaves out the number you need for a site decision.

For the same compound, a 90% reduction from 100 ng/L leaves 10 ng/L. Start at 1,000 ng/L and the same reduction leaves 100 ng/L. Those are worked examples. On a real report, read the laboratory’s definition of ND and its reporting and detection limits. For a procurement target, confirm that the agreed test can measure low enough to judge it.

[Find the named substances, concentration and reporting period in your water report](https://www.bestwaresoda.com/wiki/reading-local-water-quality-reports/)

[\[1\]](https://www.bestwaresoda.com/wiki/verifying-pfas-filter-claims/#editorial-source-1) [\[7\]](https://www.bestwaresoda.com/wiki/verifying-pfas-filter-claims/#editorial-source-7) [\[9\]](https://www.bestwaresoda.com/wiki/verifying-pfas-filter-claims/#editorial-source-9) [\[10\]](https://www.bestwaresoda.com/wiki/verifying-pfas-filter-claims/#editorial-source-10)

#### Same Percentage, Different Residuals

Inlet

**100** ng/L

Reduction

**90** %

Outlet

**10** ng/L

Inlet

**1,000** ng/L

Reduction

**90** %

Outlet

**100** ng/L

Outlet concentration = inlet concentration × (1 − reduction / 100).

Arithmetic examples for the same substance, in ng/L (nanograms per liter). These are hypothetical values, not filter test results.

### Match the Model, Cartridge and Claim

Take a photo of the system model and copy the replacement part number. Look up both in the certifier’s directory and read the claim on that row. EPA points buyers to NSF/ANSI 53 for drinking-water treatment units or NSF/ANSI 58 for reverse-osmosis systems with a relevant PFAS claim. In the NSF/ANSI 53 listing for Purity C 1000 AC, for example, the record names elements 10006721 and 10006719, with a listed service cycle of 2,642 US gallons and a flow rate of 0.79 US gal/min. The footnote for ‘Total PFAS Reduction’ names PFHpA, PFHxS, PFNA, PFOA, PFOS, PFBS and PFDA.

The NSF/ANSI 58 record for the BRDROS system gives a useful second check. It names modules BRDROF and BRDROM and lists a daily production rate of 14.76 US gallons. Among its claims are nitrate/nitrite and total dissolved solids. That row contains no PFAS claim. Use it to verify the claims it carries and request a matching result or current certification record if PFAS is a procurement requirement.

[Match the claim on the certificate to the equipment you will receive](https://www.bestwaresoda.com/wiki/read-certification-correctly/)

[\[1\]](https://www.bestwaresoda.com/wiki/verifying-pfas-filter-claims/#editorial-source-1) [\[2\]](https://www.bestwaresoda.com/wiki/verifying-pfas-filter-claims/#editorial-source-2) [\[3\]](https://www.bestwaresoda.com/wiki/verifying-pfas-filter-claims/#editorial-source-3) [\[8\]](https://www.bestwaresoda.com/wiki/verifying-pfas-filter-claims/#editorial-source-8) [\[11\]](https://www.bestwaresoda.com/wiki/verifying-pfas-filter-claims/#editorial-source-11)

A USGS scientist in black gloves collects tap water in a sample vial at a kitchen sink

Tap-water sampling for PFAS analysis. Photograph: Paul Bradley, USGS, public domain. [\[7\]](https://www.bestwaresoda.com/wiki/verifying-pfas-filter-claims/#reference-7)

| Item | Find the Specific Detail | Why It Matters |
| --- | --- | --- |
| Named Substances | The individual PFAS or defined group covered by the claim. | A result for selected compounds does not cover the whole PFAS family. |
| System and Cartridge | Exact model, compatible replacement and current listing. | A familiar brand or a similar-looking cartridge does not establish the same tested combination. |
| Concentration | Challenge-water and treated-water results, units and the stated endpoint. | A percentage and an outlet concentration answer different questions. |
| Service Conditions | Rated flow, capacity and operating or replacement requirements. | A claim applies within its documented conditions, not to unlimited use. |
| Version and Status | Standard edition, applicable transition and present certification status. | The same standard number can appear on documents from different periods. |

### Compare What the Test Actually Did

In a 2019 study at the U.S. EPA’s test facility, Craig Patterson’s team tested three reverse-osmosis systems using water prepared to simulate Colorado’s Widefield aquifer. In one unit’s restart sample at 144 hours, PFOS was 1,360 ng/L at the inlet and 77 ng/L at the outlet. The authors report 94.3% reduction. This was one result on that unit and test water, at that point in the run.

Read the performance sheet for the installed system’s flow, operating limits, rated service capacity and replacement rule. Include the installed filter stages and membrane if the claim is for an entire RO unit. Activated carbon adsorbs certain compounds, selective anion-exchange resins capture particular ions, and reverse osmosis separates a treated stream and a concentrate stream. For the purchase, match the evidence to the required compounds and expected water conditions.

[\[4\]](https://www.bestwaresoda.com/wiki/verifying-pfas-filter-claims/#editorial-source-4) [\[1\]](https://www.bestwaresoda.com/wiki/verifying-pfas-filter-claims/#editorial-source-1) [\[7\]](https://www.bestwaresoda.com/wiki/verifying-pfas-filter-claims/#editorial-source-7)

### Keep the Certification Date and Site Target Separate

A joint statement from IAPMO, NSF and WQA posted August 17, 2026 sets January 1, 2030 as the latest date for certified PFAS reduction products to demonstrate compliance with updated effluent requirements in NSF/ANSI 53-2025 and 58-2025. Ask which edition and endpoint the exact listed system supports today. Its certification timetable is separate from your water requirements. For example, the U.S. federal drinking-water rule gives covered public systems individual limits of 4.0 ng/L for PFOA and 4.0 ng/L for PFOS.

For the installation handover, keep the inlet or supply result, the target compounds, the exact system and replacement element, the data sheet and the replacement trigger together. If the job calls for outlet verification, agree on the test and reporting limit with the laboratory. Record the sample point and date, system state and time or volume since the element was fitted. That lets the next person compare the result with the right claim and the right site criterion.

[\[5\]](https://www.bestwaresoda.com/wiki/verifying-pfas-filter-claims/#editorial-source-5) [\[6\]](https://www.bestwaresoda.com/wiki/verifying-pfas-filter-claims/#editorial-source-6) [\[7\]](https://www.bestwaresoda.com/wiki/verifying-pfas-filter-claims/#editorial-source-7)

### Sources for This Edition

1. [U.S. EPA · Identifying Drinking Water Filters Certified to Reduce PFAS](https://www.epa.gov/water-research/identifying-drinking-water-filters-certified-reduce-pfas) · What Certifications Should I Look For? and When buying a water filter. EPA points to NSF/ANSI 53 or 58 with the applicable reduction claim. Consult the current certifier record and the performance sheet for the exact product.
2. [NSF International · NSF/ANSI 53 Total PFAS Reduction Listings](https://info.nsf.org/Certified/DWTU/Listings.asp?ProductFunction=053%7CTotal+PFAS+Reduction) · Nov. 25, 2026 listing snapshot. Mavea LLC, Plumbed-In, Purity C 1000 AC. Replacement elements 10006721 and 10006719 each show 2,642 gallons, 0.79 gpm and Total PFAS Reduction. Footnote \[1\] specifies PFHpA, PFHxS, PFNA, PFOA, PFOS, PFBS and PFDA.
3. [NSF International · NSF/ANSI 58 Product Listing](https://info.nsf.org/Certified/DWTU/Listings.asp?TradeName=BRDROS&Standard=058) · Nov. 25, 2026 listing snapshot. Water Channel Partners, plumbed-in to separate tap, BRDROS. Modules BRDROF and BRDROM, daily production 14.76 gpd. The displayed NSF/ANSI 58 row lists nitrate/nitrite and TDS among the claims and contains no PFAS reduction claim.
4. [Craig Patterson et al. · Effectiveness of Point-of-Use/Point-of-Entry Systems to Remove Per- and Polyfluoroalkyl Substances from Drinking Water](https://pmc.ncbi.nlm.nih.gov/articles/PMC6650157/) · AWWA Water Science 2019, e1131, DOI 10.1002/aws2.1131. Section 2.1 and Tables 1–2 describe simulated Widefield aquifer water. Section 3.1.2 and Table 7, RO system 2 after restart at 144 h, PFOS 1,360 → 77 ng/L, 94.3% reported reduction. Bench test on that unit.
5. [NSF Drinking Water Treatment Units Joint Committee · Joint PFAS Reduction Implementation Timeline](https://standards.nsf.org/discussion/dwtu-jc-joint-pfas-reduction-implementation-timeline-iapmo-nsf-and-wqa) · Posted Aug. 17, 2026. The coordinated IAPMO, NSF and WQA notice gives Jan. 1, 2030 as the latest date for products certified for PFAS reduction to demonstrate compliance with updated effluent requirements in NSF/ANSI 53-2025 and 58-2025.
6. [U.S. EPA · Final PFAS National Primary Drinking Water Regulation](https://www.epa.gov/sdwa/and-polyfluoroalkyl-substances-pfas) · Final PFAS National Primary Drinking Water Regulation table. PFOA and PFOS each have an individual MCL of 4.0 ng/L for covered public water systems. The agency also describes proposed actions published in 2026. This reference is used for the two MCL values, not a site-specific compliance determination.
7. [Massachusetts DEP · How to Interpret My PFAS Laboratory Report](https://www.capecod.gov/wp-content/uploads/2025/02/How-to-Interpret-PFAS-Laboratory-Report.pdf) · PDF p. 1, Reading the Results and the ND, RL/MRL and MDL explanations. Keep sample identification, result, units and reporting or detection limit with the laboratory’s qualifier. A non-detect has the meaning given by that method and report.
8. U.S. Geological Survey · Water Sampling for PFAS. Photograph by Paul Bradley, public domain · May 10, 2021. USGS image entry describes the scientist wearing black gloves collecting tap water in small vials at a kitchen sink. The photograph illustrates sampling.
9. Bestware Editorial · Percentage and Outlet Concentration Examples · The two retained diagrams are arithmetic for one substance. Two assumed inlet concentrations of 100 and 1,000 ng/L at 90% reduction give 10 and 100 ng/L at the outlet. No filter is attributed these results.
10. [Bestware Wiki · Reading a Local Water Quality Report](https://www.bestwaresoda.com/wiki/reading-local-water-quality-reports/) · Read the source, reporting period, named substances and results before choosing which filter claim to check.
11. [Bestware Wiki · Read a Water Equipment Certification Correctly](https://www.bestwaresoda.com/wiki/read-certification-correctly/) · Check the current certificate against the model and exact scope before signing the purchase or accepting a substitute.

1. U.S. Geological Survey · Water Sampling for PFAS. Photograph by Paul Bradley, public domain · May 10, 2021. USGS image entry describes the scientist wearing black gloves collecting tap water in small vials at a kitchen sink. The photograph illustrates sampling.

### Continue With These Decisions

- [How to Read a Local Water Quality Report for Your Tap](https://www.bestwaresoda.com/wiki/reading-local-water-quality-reports/)
  
  Find the named substances, concentration and reporting period in your water report
- [How to Check a Water Equipment Certificate Before You Buy](https://www.bestwaresoda.com/wiki/read-certification-correctly/)
  
  Match the claim on the certificate to the equipment you will receive

### Continue Exploring

Related to this article

[Water & Science 4 min read Updated 2026-11-25 Microplastics in Tap and Bottled Water: How to Compare the Counts Check the smallest particle counted, the volume and the sampling point before comparing particles per liter. Here is how those checks change a real study and a filter quote. Read article](https://www.bestwaresoda.com/wiki/reading-microplastic-evidence/)

Related to this article

[Water & Science 3 min read Source date 2026-10-15 What the 2026 Studies Found About Chloronitramide in Drinking Water Scientists have measured chloronitramide in small groups of tap-water samples and reported effects in cultured cells. The studies answer different questions. Here is what they mean when you read a water report or a filter claim. Read article](https://www.bestwaresoda.com/journal/chloronitramide-drinking-water-research-2026/)

Related to this article

[Water & Science 3 min read Updated 2026-11-25 Why Tap Water Smells Like Chlorine and What to Check First If the smell follows a clean glass away from the sink, compare cold-water outlets before ordering a filter. Where and when it happens can help you decide who should investigate. Read article](https://www.bestwaresoda.com/wiki/chlorine-chloramine-and-water-odor/)

Related to this article