A UV lamp at the bar does not clear a boil water notice. Check the address and notice first, then use a separate restart record for the coffee, ice and fountain lines.

Revised 2026-11-25

A glass beaker containing clear liquid on a laboratory stirring plate

On this page

[Put the Notice Beside the Shift Roster](https://www.bestwaresoda.com/wiki/uv-and-chemical-disinfection/#section-1) [Three Lines Behind the Counter](https://www.bestwaresoda.com/wiki/uv-and-chemical-disinfection/#section-2) [Where UV and Chemical Disinfection Do Their Work](https://www.bestwaresoda.com/wiki/uv-and-chemical-disinfection/#section-3) [Read the Class on the Issuer Record](https://www.bestwaresoda.com/wiki/uv-and-chemical-disinfection/#section-4)

### Put the Notice Beside the Shift Roster

When a boil water notice covers the café, take directly connected drink equipment out of service and check what the local food authority permits. A lit UV unit does not clear the notice. Check the address and read the wording of the notice. Boiling will not make water with harmful chemicals safe. A do-not-use order means you cannot use tap water for any purpose while it is in effect.

In the Village of Athens, New York, a July 29 storm in 2026 was followed by a boil water notice for village water customers. On August 5 the village announced the notice was lifted after testing water samples. That notice gives the public-supply status. The café still has its own equipment to prepare before staff put drinks back on sale.

[\[1\]](https://www.bestwaresoda.com/wiki/uv-and-chemical-disinfection/#editorial-source-1) [\[6\]](https://www.bestwaresoda.com/wiki/uv-and-chemical-disinfection/#editorial-source-6)

### Three Lines Behind the Counter

Picture a café with a plumbed espresso machine, an ice maker and a post-mix fountain. Tag the three branches on a sheet. Keep the machines on hold while you check what the notice permits. New York State’s food-service guidance keeps directly connected post-mix and ice machines off, and calls for discarding ice if its production time can’t be verified. It allows a coffee maker that actually meets its heat and hold conditions. Boston’s local guide tells operators to shut off the brewer. Ask the relevant authority before deciding which equipment and approved supplies the café can use.

When the notice lifts, hand the equipment list to the person responsible for the plumbing and the food lead. Record the official release separately from flushing the affected building lines, flushing and sanitizing each machine, or servicing a filter according to its instructions. The ice bin and scoop are part of the ice job. Enter who completed the equipment work and when it was cleared to serve. A line that has yet to be checked stays out of service.

[\[7\]](https://www.bestwaresoda.com/wiki/uv-and-chemical-disinfection/#editorial-source-7) [\[8\]](https://www.bestwaresoda.com/wiki/uv-and-chemical-disinfection/#editorial-source-8) [\[12\]](https://www.bestwaresoda.com/wiki/uv-and-chemical-disinfection/#editorial-source-12) [\[1\]](https://www.bestwaresoda.com/wiki/uv-and-chemical-disinfection/#editorial-source-1)

### Where UV and Chemical Disinfection Do Their Work

Mark the UV reactor on the water drawing, along with any tank and the pipes after it. UV can inactivate microorganisms as water passes the reactor. It leaves no disinfectant residual in that tank or downstream pipe. Some chemical disinfectants can leave a residual in the distribution network, under conditions set by the supply operator. That residual and the outlet conditions both matter. Ordinary disinfection UV does not remove dissolved chemicals.

At purchase or recommissioning, ask for the exact unit’s validated flow range, which water-quality limits apply, and what the system monitors when it detects low performance. UV transmittance describes how much UV passes through the water. Lamp age and fouling can matter even when the lamp is on. Put the alarm response in the operating sheet so a shift lead knows which outlet to stop using and who checks it.

[\[3\]](https://www.bestwaresoda.com/wiki/uv-and-chemical-disinfection/#editorial-source-3) [\[2\]](https://www.bestwaresoda.com/wiki/uv-and-chemical-disinfection/#editorial-source-2)

### Read the Class on the Issuer Record

Health Canada describes NSF/ANSI 55 Class B as additional bactericidal treatment for water already suitable to drink. Its Class A description allows disinfection of water with microbial contamination under the applicable conditions and excludes water contaminated by raw sewage. Compare the complete model number and class with the certification record and the manufacturer’s operating limits. If the installation includes a tank after UV, put that part of the route in the maintenance and restart plan as well.

[Use the handover sheet to track each outlet’s work and sign-off](https://www.bestwaresoda.com/wiki/handover-water-stations-to-site-teams/)

[\[4\]](https://www.bestwaresoda.com/wiki/uv-and-chemical-disinfection/#editorial-source-4) [\[5\]](https://www.bestwaresoda.com/wiki/uv-and-chemical-disinfection/#editorial-source-5) [\[11\]](https://www.bestwaresoda.com/wiki/uv-and-chemical-disinfection/#editorial-source-11) [\[10\]](https://www.bestwaresoda.com/wiki/uv-and-chemical-disinfection/#editorial-source-10)

### Sources for This Edition

1. [CDC · Drinking Water Advisories: An Overview](https://www.cdc.gov/water-emergency/about/drinking-water-advisories-an-overview.html) · Boil water, Do not drink, and Do not use sections. The correct action depends on what the notice says and on local instructions.
2. [CDC · About Home Water Treatment Systems](https://www.cdc.gov/drinking-water/about/about-home-water-treatment-systems.html) · Ultraviolet treatment systems section. UV treats microorganisms and does not remove chemicals; the page discusses household systems.
3. [NHMRC · Australian Drinking Water Guidelines: 1.7 Disinfection with Ultraviolet Light](https://guidelines.nhmrc.gov.au/australian-drinking-water-guidelines/part-4/disinfection/1.7-disinfection-with-ultraviolet-light) · Scientific Basis and Operational Monitoring sections. UV dose, transmittance, fouling and downstream residual. Public-supply technical guidance.
4. [Health Canada · Drinking Water and Health: Treatment](https://www.canada.ca/en/health-canada/services/environment/drinking-water/treatment.html) · NSF/ANSI standard 55 section. Class A and B have different uses, with raw sewage outside the stated Class A use.
5. [NSF · Certified Point-of-Entry Drinking Water Treatment Units, Standard 55](https://info.nsf.org/Certified/DWTU/Listings.asp?ProductType=Point-of-Entry&Standard=055&hdModlStd=ModlStd) · Official directory result filtered to Standard 055 and Point-of-Entry. Examples show the class and model in the record, not a certification for any product used in the example.
6. [Village of Athens, New York · Athens Boil Water Notice Lifted: 8/5/26](https://athensvillageny.gov/2026/08/05/athens-boil-water-notice-lifted-8-5-26/) · August 5, 2026 notice. Applies to the village’s municipal water customers after the July 29 storm; the notice cites tested samples.
7. [New York State Department of Health · Boil Water Notices: Food Service Operator FAQ](https://healthweb-back.health.ny.gov/environmental/water/drinking/boilwater/docs/faq_food_service_establishments.pdf) · Pages 1–2: operating conditions, approved alternatives, post-mix beverages and ice. Page 4: flushing, connected equipment, filters and sanitation after lifting. Original state-hosted PDF.
8. [City of Boston · Spanish Small Business Emergency Action Plan and Response Guide](https://www.boston.gov/sites/default/files/file/2025/10/3.%20Emergency%20Action%20Plan%20and%20Response%20Guides_0.pdf) · Physical PDF pages 34–35: water contamination or boil notice regarding coffee, ice and beverage equipment. Local guidance for Boston.
9. [GB 31654-2021 · 餐饮服务通用卫生规范](https://www.hbhr.gov.cn/hrqxxgk/xxgkml/gyxsy/spaq/202105/P020210517344677417263.pdf) · Chinese government copy. Section 4.1.2 requires water for food processing to meet GB 5749 and applicable special requirements.
10. [Bestware Wiki · Handing Over Water Stations to Site Teams](https://www.bestwaresoda.com/wiki/handover-water-stations-to-site-teams/) · Use the handover sheet to record line, status, restart evidence and who signed.
11. [Bestware Wiki · NSF Point-of-Use Certification Scope](https://www.bestwaresoda.com/wiki/nsf-point-of-use-scope/) · Use a real directory to match exact model and performance claim.
12. Bestware · Illustrative Café Closure and Restart Work Order · Hypothetical coffee, ice and post-mix branches. Split drinking water notice and site permit from the equipment flush, removal of suspect ice and signed reopening. No named café or field test.

### Continue With These Decisions

- [How to Hand Over a Water Station to the Site Team](https://www.bestwaresoda.com/wiki/handover-water-stations-to-site-teams/)
  
  Use the handover sheet to track each outlet’s work and sign-off
- [Does a Point-of-Use Water Filter Need NSF 61?](https://www.bestwaresoda.com/wiki/nsf-point-of-use-scope/)
  
  Check the exact listed model, its UV class and its certification scope.

### Continue Exploring

Related to this article

[Water & Science 3 min read Source date 2026-10-15 What the 2026 Studies Found About Chloronitramide in Drinking Water Scientists have measured chloronitramide in small groups of tap-water samples and reported effects in cultured cells. The studies answer different questions. Here is what they mean when you read a water report or a filter claim. Read article](https://www.bestwaresoda.com/journal/chloronitramide-drinking-water-research-2026/)

Related to this article

[Water & Science 5 min read Updated 2026-11-25 What Restaurants Should Stop During a Water Advisory Read the notice for your address before using the tap. Then mark off the ice, drinks, prep and washing that depend on it, and reopen each station only after the required checks. Read article](https://www.bestwaresoda.com/wiki/boiling-filtration-and-emergency-water/)

Related to this article

[Water & Science 3 min read Updated 2026-11-25 Why Tap Water Smells Like Chlorine and What to Check First If the smell follows a clean glass away from the sink, compare cold-water outlets before ordering a filter. Where and when it happens can help you decide who should investigate. Read article](https://www.bestwaresoda.com/wiki/chlorine-chloramine-and-water-odor/)

Related to this article