# How to Test a Table-Side Hot-Water Control

Source: https://www.bestwaresoda.com/wiki/test-table-side-hot-water-controls/
Language: en-US

[Back to Water Wiki](https://www.bestwaresoda.com/wiki/)

Technology & Design

## How to Test a Table-Side Hot-Water Control

Use the cups the venue serves, check how hot water starts and stops, and leave a record staff can use on the next shift.

Revised 2026-11-25

A ceramic cup and dispensing outlet at a restaurant counter

On this page

[Start With the Cup Your Servers Reach For](https://www.bestwaresoda.com/wiki/test-table-side-hot-water-controls/#section-1) [Find out What Starts and Stops the Flow](https://www.bestwaresoda.com/wiki/test-table-side-hot-water-controls/#section-2) [Watch the Water After the Stop Command](https://www.bestwaresoda.com/wiki/test-table-side-hot-water-controls/#section-3) [Read the Warning From the Guest’s Side](https://www.bestwaresoda.com/wiki/test-table-side-hot-water-controls/#section-4) [Leave the Next Shift a Way to Check](https://www.bestwaresoda.com/wiki/test-table-side-hot-water-controls/#section-5)

### Start With the Cup Your Servers Reach For

You can check most of the layout before the heater is on. Put the smallest cup you serve under the spout, then try the tallest. Both should sit flat on the tray or holder intended for them. See where a handle lands, whether there is room to bring the cup in and take it away, and whether the hot-water symbol is still visible with the cup in place. Test those movements with an empty cup. The hot run comes after the layout and controls are clear.

Record the dispenser model, the tap or control revision and the manual supplied with the unit. If sparkling, chilled and hot water share a panel, make sure each service mode is recognizable from the point where the person actually stands. Record who may use the hot function during normal service. The test for a staff-only counter may call for a different arrangement from a station guests can walk up to.

[\[1\]](https://www.bestwaresoda.com/wiki/test-table-side-hot-water-controls/#editorial-source-1)

### Find out What Starts and Stops the Flow

On the G1DS-123 and G1DS-1023 control shown in Bestware’s V1.2 manual, the hot-water screen has a separate unlock step. After choosing Hot Water and pressing to unlock, the manual calls for pressing the center button within 0.8 seconds. After flow starts, the display counts down and shows “Press to stop.” The same manual shows a center press to dispense in the cold, sparkling and ambient modes after selection. Have the technician record what the installed tap actually does after an unlock expires, when the operator stops a pour, and when the programmed run ends.

Check those actions against the documentation for the control in front of you. The FETCO HWD-2102 manual, for instance, describes a manual mode that dispenses while the operator holds the button and a portion mode that finishes its set portion after release. For a timed mode, verify a clear early-stop action and check the full delivery against the cup’s working fill line. These are model and mode details worth making explicit on the handover sheet.

[\[1\]](https://www.bestwaresoda.com/wiki/test-table-side-hot-water-controls/#editorial-source-1) [\[2\]](https://www.bestwaresoda.com/wiki/test-table-side-hot-water-controls/#editorial-source-2)

### Watch the Water After the Stop Command

With the station closed to guests, have a qualified commissioning technician use the approved test procedure, a stable heat-rated vessel, a splash-controlled area and a suitable thermometer. Keep hands clear of the stream. Use the real cup geometry only where it is suitable for hot service and the test. Measure the delivery on the first pour after a pause and during repeated service as permitted by the manufacturer. Record the control setting, the temperature actually measured in the receiving vessel, the stop command, when the stream ceased, and how much ended up in the cup after drips. Leave the vessel in place until the flow and drips have stopped.

Suppose the smallest service cup has a working fill line at 180 mL, and the timed test delivers 195 mL including drips. That is 15 mL above the working line. Keep hot service out of use until the programmed portion or permitted cup lineup is corrected. Then repeat the normal finish and early stop tests. Record the accepted cup and setting, so the next person can tell whether a change has invalidated the result.

[\[1\]](https://www.bestwaresoda.com/wiki/test-table-side-hot-water-controls/#editorial-source-1)

### Read the Warning From the Guest’s Side

In October and November 2006, researchers bought 164 small black coffees at drive-throughs in central Michigan and New York’s Finger Lakes region. They reported that some printed warnings were hidden by sleeves. Their study followed served coffees. At a table-side dispenser, the same visibility question is worth checking from the approach, with the cup in position and the usual sleeve, tray or menu stand in place.

For U.S. projects where ADA §309.4 applies, operable parts must be usable with one hand, without tight grasping, pinching or twisting of the wrist, and with no more than 5 pounds of force. Work through access and usability with a dry setup and let the project team resolve any conflict with the documented hot-water sequence. The project team should also define the acceptance criterion for temperature at this station and check it against the reading in the receiving vessel. Keep the control’s setpoint beside that reading so both can be traced after a setting change.

[Check approach, reach and cup handling for an accessible drinking point](https://www.bestwaresoda.com/wiki/accessible-drinking-water-points/)

[\[3\]](https://www.bestwaresoda.com/wiki/test-table-side-hot-water-controls/#editorial-source-3) [\[4\]](https://www.bestwaresoda.com/wiki/test-table-side-hot-water-controls/#editorial-source-4) [\[5\]](https://www.bestwaresoda.com/wiki/test-table-side-hot-water-controls/#editorial-source-5)

### Leave the Next Shift a Way to Check

Post the agreed cup and stop instructions near the fixture. In the handover record, name the person who can change dosing, verify the supplier’s approved restart procedure with the station out of guest use, and assign a retest after a control, tray or cup change. If a stop command, fill or access check is still unresolved, give staff a way to take the hot mode out of service and record who clears it for use.

[Put hot-mode acceptance and restart checks on the installation handover](https://www.bestwaresoda.com/wiki/water-system-installation-and-handover/)

[\[6\]](https://www.bestwaresoda.com/wiki/test-table-side-hot-water-controls/#editorial-source-6)

### Sources for This Edition

1. [Bestware — G1DS-123 / G1DS-1023 Instruction Manual, V1.2](https://www.bestwaresoda.com/assets/documents/g1ds-123-g1ds-1023-installation-manual-2026-v1.2-en.pdf) · PDF p. 3, printed pp. 01–02, cold, sparkling and ambient operation and separate Hot Water unlock and center button within 0.8 s, countdown and Press to stop. PDF p. 4, printed p. 04, heating-temperature setting.
2. FETCO — Dispensador de agua caliente HWD-2102, P119SPA · PDF p. 3, manual dispensing while finger stays on the button, and selected portion completion after release.
3. [Carl P. Borchgrevink, Michael P. Sciarini and Alex M. Susskind — Hot Beverages at Quick Service Restaurant (QSR) Drive-Thru Windows](https://ecommons.cornell.edu/bitstream/1813/71605/1/Susskind13_Hot_Beverages.pdf) · Journal of Hospitality and Tourism Management 14(1), 37–46, 2007. Repository PDF pp. 12–13, Methods, Results and Warnings; 164 small black coffees and written warning visibility.
4. [U.S. Access Board — ADA Guide, Chapter 3, Operable Parts](https://www.access-board.gov/ada/guides/chapter-3-operable-parts/) · Operable Parts §309, Operation §309.4; one-hand operation, no tight grasping, pinching or wrist twisting, and 5 lbf maximum where applicable.
5. [Bestware Wiki — Accessible Drinking Water Points](https://www.bestwaresoda.com/wiki/accessible-drinking-water-points/) · Check the full approach, controls, container handling and use case.
6. [Bestware Wiki — Water Dispenser Installation and Handover](https://www.bestwaresoda.com/wiki/water-system-installation-and-handover/) · Carry model, observed operation and unresolved defects into site acceptance and training.

### Continue With These Decisions

- [How to Specify an Accessible Drinking Water Point](https://www.bestwaresoda.com/wiki/accessible-drinking-water-points/)
  
  Check approach, reach and cup handling for an accessible drinking point
- [Water Dispenser Installation and Handover: What to Sign Off](https://www.bestwaresoda.com/wiki/water-system-installation-and-handover/)
  
  Put hot-mode acceptance and restart checks on the installation handover

### Continue Exploring

Related to this article

[Technology & Design 4 min read Updated 2026-11-24 How to Test a Metering Faucet Before You Approve It Time one press, collect the whole discharge and try the installed basin as someone would use it. Keep the accessibility check and the product water-use report with that same configuration. Read article](https://www.bestwaresoda.com/wiki/accept-metering-faucet-cycles/)

Related to this article

[Technology & Design 4 min read Updated 2026-11-24 How to Test a Commercial Pre-Rinse Spray Valve Before You Accept It Use a real rack of dishes. Count the extra passes, read the meter and check that the hand spray closes when the operator lets go. Read article](https://www.bestwaresoda.com/wiki/accept-pre-rinse-spray-valves/)

Related to this article

[Technology & Design 4 min read Updated 2026-11-25 How to Test a Sensor Faucet in the Installed Basin Pilot a real pair of wash stations, count missed and unintended starts separately and keep the settings that produced the result. Read article](https://www.bestwaresoda.com/wiki/accept-sensor-faucets-in-the-installed-basin/)