Identify the seal and joint, check what the certification actually covers, and ask for a test record tied to the parts you will receive.

Revised 2026-11-24

Hands holding a metal faucet assembly over a workbench fixture

On this page

[Describe the Joint Before Picking the Rubber](https://www.bestwaresoda.com/wiki/specify-seals-and-leak-tests/#section-1) [Read the Listing for the Item Being Purchased](https://www.bestwaresoda.com/wiki/specify-seals-and-leak-tests/#section-2) [Ask What the Leakage Test Measured](https://www.bestwaresoda.com/wiki/specify-seals-and-leak-tests/#section-3) [Use a Published Test Note to Ask for the Batch Record](https://www.bestwaresoda.com/wiki/specify-seals-and-leak-tests/#section-4) [Make the Receiving Record Usable at the Workbench](https://www.bestwaresoda.com/wiki/specify-seals-and-leak-tests/#section-5)

### Describe the Joint Before Picking the Rubber

Start the purchase specification with the location of the seal. A fixed cold-water inlet and the seal in a swivel may see the same water and behave very differently in use. Mark which surfaces the seal touches, whether it moves, and the drawing revision for the groove and mating parts. Record the seal part number, exact compound, hardness, and dimensions with tolerances. A label that says EPDM or silicone gives the family. The supplier needs the specific compound to check the proposed duty.

List the water conditions and the rest of the exposure. Include working temperature and pressure together, normal starts or movement, and any cleaner, sanitizer or lubricant that contacts the seal. For cleaning, tell the supplier the actual chemical, concentration, temperature, contact time and frequency. Have the supplier confirm that combination for the compound and joint. A trial on the proposed assembly is especially useful when motion or repeated cleaning is part of the job.

[\[1\]](https://www.bestwaresoda.com/wiki/specify-seals-and-leak-tests/#editorial-source-1) [\[2\]](https://www.bestwaresoda.com/wiki/specify-seals-and-leak-tests/#editorial-source-2)

### Read the Listing for the Item Being Purchased

For a project requiring North American drinking-water documentation, start with the scope of each standard. NSF/ANSI/CAN 61 evaluates health effects from substances that can leach into drinking water. NSF/ANSI/CAN 372 addresses lead content. The public scope of ASME A112.18.1-2024/CSA B125.1-2024 covers specified plumbing supply fittings such as kitchen fittings and commercial pre-rinse spray valves. Check the project’s required edition and the exact assembly in the certifier’s listing.

When a gasket or compound listing is part of the order, check the trade designation, covered item, plant where shown, water-contact conditions and footnotes. For example, the NSF listing shows two EPDM designations, RR809 EPDM70P and RR884 EPDM60S, with different restrictions for use in mechanical plumbing devices. Match the actual seal to its entry. When the order also requires a listed finished fitting, check the model and configuration on its own listing and keep that evidence with the order.

[\[3\]](https://www.bestwaresoda.com/wiki/specify-seals-and-leak-tests/#editorial-source-3) [\[4\]](https://www.bestwaresoda.com/wiki/specify-seals-and-leak-tests/#editorial-source-4) [\[5\]](https://www.bestwaresoda.com/wiki/specify-seals-and-leak-tests/#editorial-source-5) [\[6\]](https://www.bestwaresoda.com/wiki/specify-seals-and-leak-tests/#editorial-source-6)

### Ask What the Leakage Test Measured

Give working conditions, proof testing and leak testing their own lines on the acceptance sheet. For the leak test, agree which ports and seals are included, the medium, pressure and temperature, the stabilization and measurement intervals, and the acceptance criterion with its units. Ask how external leakage and any internal bypass are assessed when both matter. A short check at one pressure answers a different question from repeat cycling under the agreed duty.

If the approved test uses an air pressure-decay bench, the test fixture and temperature can affect the reading. Ask the supplier’s qualified team how it checks the fixture and instrument and what the recorded value means. A pressure change over time and a reported leak rate use different units and require the specified method for comparison. A visual water check should identify where the observer looked and what counted as leakage.

[\[1\]](https://www.bestwaresoda.com/wiki/specify-seals-and-leak-tests/#editorial-source-1) [\[7\]](https://www.bestwaresoda.com/wiki/specify-seals-and-leak-tests/#editorial-source-7) [\[8\]](https://www.bestwaresoda.com/wiki/specify-seals-and-leak-tests/#editorial-source-8) [\[6\]](https://www.bestwaresoda.com/wiki/specify-seals-and-leak-tests/#editorial-source-6)

### Use a Published Test Note to Ask for the Batch Record

Bestware’s published note on its European-style and American-style pre-rinse faucets describes a union with two O-rings and lists a 1.0 MPa leakage test for those series. For an actual order, check the drawing of the quoted joint and ask which assembly was tested, under what procedure and for how long. Confirm the permitted working conditions from the quoted specification. Request the test record for the shipment so the series description has a traceable counterpart for the hardware being delivered.

[\[9\]](https://www.bestwaresoda.com/wiki/specify-seals-and-leak-tests/#editorial-source-9) [\[1\]](https://www.bestwaresoda.com/wiki/specify-seals-and-leak-tests/#editorial-source-1) [\[7\]](https://www.bestwaresoda.com/wiki/specify-seals-and-leak-tests/#editorial-source-7)

### Make the Receiving Record Usable at the Workbench

For a sample receiving sheet, use a fictitious entry such as cold-water inlet union J-01, housing revision B, seal lot DEMO-L01. Attach the approved drawing and the actual material and lot labels. Leave space for the approved method and revision, instrument ID, test conditions, criterion and units, measured result, tester and date. This example remains pending and on hold until those checks are completed. In a real shipment, record whether the test covered every unit or an agreed sample and connect the record to the units or lot inspected.

If a seal, supplier, groove or assembly process changes, use the change record to identify which compatibility, listing and test evidence needs refreshing. After a repair, have qualified personnel follow the model’s isolation and service instructions and carry out the agreed installed check. Give the next technician the replacement part reference and the record of what was actually changed.

[\[11\]](https://www.bestwaresoda.com/wiki/specify-seals-and-leak-tests/#editorial-source-11) [\[1\]](https://www.bestwaresoda.com/wiki/specify-seals-and-leak-tests/#editorial-source-1) [\[3\]](https://www.bestwaresoda.com/wiki/specify-seals-and-leak-tests/#editorial-source-3) [\[8\]](https://www.bestwaresoda.com/wiki/specify-seals-and-leak-tests/#editorial-source-8) [\[10\]](https://www.bestwaresoda.com/wiki/specify-seals-and-leak-tests/#editorial-source-10)

### Sources for This Edition

1. Parker Prädifa O-Ring Guide — Application and Material Compatibility · PDF pages 4–5, Range of application, Compatibility of seals and operating media / cleaning agents, and Prototypes and samples.
2. Parker O-Ring Selector · Material and Size inputs. Selection tool, not an approval for the finished assembly or the proposed order.
3. [NSF — Gasket and Gasket Material Certification](https://www.nsf.org/water-systems/gasket-material-certification) · Health-effects scope for chemical contaminants leaching into drinking water, and separate material, gasket and gasket-cutter certification services.
4. [NSF/ANSI/CAN 61 Official Listing — Gasket Materials and O-Rings](https://info.nsf.org/Certified/PwsComponents/Listings.asp?Company=C0161804&Standard=061) · NSF official readback November 24, 2026. RR809 EPDM70P footnote 1 and RR884 EPDM60S footnote 3 in the Gasket/Sealing Materials and O-Rings tables. Their 2.0 and 0.4 sq. in./L values are Mechanical Plumbing Device application restrictions. Footnote 2 separately lists the general maximum as 2.0 sq. in./L for the relevant rows.
5. [NSF/ANSI/CAN 372 — Technical Requirements](https://www.nsf.org/knowledge-library/nsf-ansi-can-372-technical-requirements) · What the standard covers, lead content only. Extraction or leaching is covered separately.
6. [ASME A112.18.1-2024 / CSA B125.1-2024 — Plumbing Supply Fittings](https://webstore.ansi.org/standards/csa/csaasmea112182024b125) · CSA-published Preface and §§1.1–1.3. The respective inclusions and exclusions apply to the cited edition. Only the public scope is used here, with no universal test values asserted.
7. ATEQ F620 Operating Manual — Pressure-Decay Measurement · Sheet 673u, §3.1.3 Direct pressure measurement, and the stabilization time description. Supports separate intervals and control of pressure and temperature. This instrument is a method source, not identification of the Bestware bench.
8. ATEQ — Leak Test Fixture Design · Fixture Structure, Temperature, Volume, Fixture Connections and Environmental Conditions. Supports recording the test setup and checking false indications from the fixture.
9. [Bestware — Leak Prevention in European-Style and American-Style Pre-Rinse Faucets](https://www.bestware-stainless.com/News&Blog/3-Key-Reasons-Why-Bestware-Pre-Rinse-Faucets-Excel-in-Leak-Prevention) · October 25, 2025, §2.3 Union Joint and §3 Leakage Test, plus the final scope note. The company describes a two-O-ring union and a series leakage test of 1.0 MPa. The specific batch, approved working pressure, dwell and independent model result are not published there.
10. [Bestware — Commercial Faucet Troubleshooting Guide](https://www.bestware-stainless.com/sup_guide.html) · Pre Rinse Faucet, Leakage at connection points, TG4. Identifies checking for damaged O-rings at joints. Follow the applicable service instructions for the exact product.
11. Illustrative seal and leak-test receiving record · Fictitious job record for a static cold-water inlet union J-01 with housing revision B and seal lot DEMO-L01. No product model, lot test, numeric setting, tolerance or result is asserted. Status in example is pending and held.

### Continue With These Decisions

- [How to Check a Water Equipment Certificate Before You Buy](https://www.bestwaresoda.com/wiki/read-certification-correctly/)
  
  Match the listing scope to the seal and finished fitting.
- [How to Test a Commercial Pre-Rinse Spray Valve Before You Accept It](https://www.bestwaresoda.com/wiki/accept-pre-rinse-spray-valves/)
  
  Plan acceptance of the complete pre-rinse valve.

### Continue Exploring

Related to this article

[Technology & Design 3 min read Updated 2026-11-25 How to Compare Faucet Machining Costs Put both quotes on the same drawing and acceptance criteria. Then compare what each batch costs per usable part and when those parts can ship. Read article](https://www.bestwaresoda.com/wiki/compare-faucet-materials-and-machining-costs/)

Related to this article

[Technology & Design 4 min read Updated 2026-11-25 How to Specify and Care for Stainless Steel Surfaces Put the alloy, the finished surface and the cleaning procedure on the purchase record. When a mark appears, check where it started before deciding which part needs work. Read article](https://www.bestwaresoda.com/wiki/specify-stainless-steel-and-surface-care/)

Related to this article

[Technology & Design 4 min read Updated 2026-11-25 Does the French ACS Cover the Tap and Hose You’re Buying? For a French project, match the certificate and its annex to the exact water-contact assembly. Then check the December 2026 cutoff and any component changes before accepting the order. Read article](https://www.bestwaresoda.com/wiki/verify-french-acs-and-eu-water-contact-transition/)

Related to this article