# Commercial Kitchen Hose Reels: Reach, Wall Fit and Service Access

Source: https://www.bestwaresoda.com/wiki/specify-commercial-kitchen-hose-reels/
Language: en-US

[Back to Water Wiki](https://www.bestwaresoda.com/wiki/)

Technology & Design

## Commercial Kitchen Hose Reels: Reach, Wall Fit and Service Access

Compare the open HRMO-R1500-NLH and enclosed HRELG-R1500-NLH. Use the actual washdown route and the dimension drawings to check clearance before you drill.

Revised 2026-11-24

Bestware HRELG-R1500-NLH enclosed wall-mounted hose reel with its top handle and guide outlet

On this page

[Measure to the Spot Staff Actually Wash](https://www.bestwaresoda.com/wiki/specify-commercial-kitchen-hose-reels/#section-1) [Compare the Return and the Guide Separately](https://www.bestwaresoda.com/wiki/specify-commercial-kitchen-hose-reels/#section-2) [Read the Dimensions From the Right Starting Point](https://www.bestwaresoda.com/wiki/specify-commercial-kitchen-hose-reels/#section-3) [Put a Pass or a Fix on the Handover Sheet](https://www.bestwaresoda.com/wiki/specify-commercial-kitchen-hose-reels/#section-4)

### Measure to the Spot Staff Actually Wash

Mark the last floor drain or work area to be washed. Have the person who closes the kitchen walk from the proposed hose outlet to that spot, starting with the prep tables and carts in their usual positions. Take the measurement along that route. Mark the corner that the hose rubs, the door it crosses and the spot where the operator can stand while using the gun.

In a planning example, the tape follows 9.2 m along a bench, 3.6 m around its end and a final 1.5 m to the working position. That is 14.3 m on paper, leaving 0.7 m against a nominal 15 m hose. An installer still needs to run the actual assembly with the stop and nozzle fitted. Have the operator reach the last point, stop and bring the hose back without pulling across the door or working against the end stop.

[\[1\]](https://www.bestwaresoda.com/wiki/specify-commercial-kitchen-hose-reels/#editorial-source-1) [\[2\]](https://www.bestwaresoda.com/wiki/specify-commercial-kitchen-hose-reels/#editorial-source-2) [\[5\]](https://www.bestwaresoda.com/wiki/specify-commercial-kitchen-hose-reels/#editorial-source-5)

### Compare the Return and the Guide Separately

Bestware lists 15 m and a hose diameter of 20 mm on both product sheets. The HRMO-R1500-NLH has an open SUS304 reel on a wall mount. A technician can see the wound hose directly. The HRELG-R1500-NLH has an ABS enclosure on a detachable wall mount. Plan room to handle the unit during service, alongside the space it occupies every day.

Both sheets list semi-automatic hose return. The enclosed model also lists automatic reeling. Its feature description ties that second term to guiding the hose across the reel as it moves in and out. At the demonstration, watch a normal return from the closest wash point and then from the farthest one. Note where the hose lands on the drum, whether it stacks or rubs, and whether the gun parks within reach.

[\[1\]](https://www.bestwaresoda.com/wiki/specify-commercial-kitchen-hose-reels/#editorial-source-1) [\[2\]](https://www.bestwaresoda.com/wiki/specify-commercial-kitchen-hose-reels/#editorial-source-2)

### Read the Dimensions From the Right Starting Point

The 2026 V1.6 catalogue drawings give the open reel spans as 492 × 260 × 458 mm and the enclosed spans as 582 × 232 × 503 mm. The enclosed drawing measures 445 mm to the casing top and 503 mm to the handle top from the same lower line. The separate product-page size fields still list 475 × 515 × 455 mm and 578.5 × 248 × 446 mm respectively. Mark the actual drawing dimensions and their starting points on the site sketch, then match the revision to the order before approving the wall opening.

Draw the reel in its parked position first, then add the movement that happens during work and service. Include the gun hanging in its parking position, the direction of payout, the hose bend at the feed connection, the door swing and the space to get a tool onto the fittings. Leave removal clearance pending until the installer has checked the actual bracket and lifting path at the finished wall.

[\[8\]](https://www.bestwaresoda.com/wiki/specify-commercial-kitchen-hose-reels/#editorial-source-8) [\[3\]](https://www.bestwaresoda.com/wiki/specify-commercial-kitchen-hose-reels/#editorial-source-3) [\[4\]](https://www.bestwaresoda.com/wiki/specify-commercial-kitchen-hose-reels/#editorial-source-4) [\[5\]](https://www.bestwaresoda.com/wiki/specify-commercial-kitchen-hose-reels/#editorial-source-5)

### Put a Pass or a Fix on the Handover Sheet

Take the feed into the same handover. Allocate the isolation valve, drain arrangement and any required backflow protection to the plumbing scope. The published Iowa Clarinda kitchen project, for example, shows the reel connection and the control-cabinet door on one detail and assigns backflow prevention separately. Virginia’s food-establishment rule gives a concrete example of point-of-use protection on a hose connection. Have the project designer confirm the device for the local installation. The gun’s product check-valve feature is a separate line in the record.

Ask for a shop drawing with the exact model, wall face, bracket fixings, connection path and access direction. On site, mark the closest and farthest wash positions tested, the return path, gun parking, leaks and access to shut off the water. Record the fitting or layout change and repeat the affected check before handing the station over.

[Use the existing-fixture guide to record the old mounting points and connections](https://www.bestwaresoda.com/wiki/replace-water-fixtures-in-existing-counters/)

[\[5\]](https://www.bestwaresoda.com/wiki/specify-commercial-kitchen-hose-reels/#editorial-source-5) [\[6\]](https://www.bestwaresoda.com/wiki/specify-commercial-kitchen-hose-reels/#editorial-source-6) [\[2\]](https://www.bestwaresoda.com/wiki/specify-commercial-kitchen-hose-reels/#editorial-source-2) [\[7\]](https://www.bestwaresoda.com/wiki/specify-commercial-kitchen-hose-reels/#editorial-source-7)

### Sources for This Edition

1. [Bestware HRMO-R1500-NLH · Product specifications](https://www.bestware-stainless.com/Products/Hose-Reel/Open-Style/HRMO-R1500-NLH) · Specifications: wall mount, open SUS304 reel, semi-auto rewinding, 15 m hose, listed hose diameter 20 mm, maximum 80 °C and 1.03 MPa.
2. [Bestware HRELG-R1500-NLH · Product specifications](https://www.bestware-stainless.com/Products/Hose-Reel/Enclosed-Style/HRELG-R1500-NLH) · Specifications and Features: detachable wall mount, ABS enclosure listing, 15 m hose, rewinding Semi-auto, guide reeling Auto with hose alignment in both directions.
3. [Bestware HRMO-R1500-NLH · Dimension drawing](https://www.bestware-stainless.com/upload/editorfile/202604/HRMO-R1500-NLH.pdf#page=1) · Page 1: 492 mm horizontal drawing dimension from the mounting side to the guide-side end; reel Ø455 mm; separate Product Size field 475 × 515 × 455 mm.
4. [Bestware HRELG-R1500-NLH · Dimension drawing](https://www.bestware-stainless.com/upload/editorfile/202602/HRELG-R1500-NLH.pdf#page=1) · Page 1: front-view vertical lines to housing top 445 mm and handle top 503 mm, from a shared lower datum. Product Size field separately lists 578.5 × 248 × 446 mm.
5. [Iowa Clarinda Kitchen & Laundry Addition · Mechanical detail FSM101](https://bidopportunities.iowa.gov/Home/GetBidOpportunityDocument/cb761c0d-2523-4b6d-bb62-c78f3b1019f9#page=11) · FSM101, HOSE REEL detail: wall face, supports and service connections, control cabinet open-door position, and division of trade responsibilities.
6. [Virginia Administrative Code 12VAC5-421-2260](https://law.lis.virginia.gov/admincode/title12/agency5/chapter421/section2260/) · Backflow prevention at the point of use, including an attached hose in food establishments in Virginia.
7. [Measure an existing fixture before replacing it](https://www.bestwaresoda.com/wiki/replace-water-fixtures-in-existing-counters/) · Site guide to recording existing openings, supports and access before cutting or changing plumbing.
8. [Bestware Catalogue 2026 V1.6 · Wall-mounted hose reel drawings](https://www.bestware-stainless.com/upload/editorfile/202611/Bestware-Catalog-2026-V1.6.pdf#page=59) · PDF page 59, printed page 102. Open HRMO 492 × 260 × 458 mm; enclosed HRELG 582 × 232 × 503 mm. These entries agree with the labeled spans in the two views.

### Continue With These Decisions

- [How to Test a Commercial Pre-Rinse Spray Valve Before You Accept It](https://www.bestwaresoda.com/wiki/accept-pre-rinse-spray-valves/)
  
  Check shutoff, spray coverage and handling at the nozzle on the installed line.
- [Water Dispenser Installation and Handover: What to Sign Off](https://www.bestwaresoda.com/wiki/water-system-installation-and-handover/)
  
  Record equipment, plumbing responsibilities and the installed tests in the handover.

### Continue Exploring

Related to this article

[Technology & Design 4 min read Updated 2026-11-24 How to Test a Metering Faucet Before You Approve It Time one press, collect the whole discharge and try the installed basin as someone would use it. Keep the accessibility check and the product water-use report with that same configuration. Read article](https://www.bestwaresoda.com/wiki/accept-metering-faucet-cycles/)

Related to this article

[Technology & Design 4 min read Updated 2026-11-24 How to Test a Commercial Pre-Rinse Spray Valve Before You Accept It Use a real rack of dishes. Count the extra passes, read the meter and check that the hand spray closes when the operator lets go. Read article](https://www.bestwaresoda.com/wiki/accept-pre-rinse-spray-valves/)

Related to this article

[Technology & Design 4 min read Updated 2026-11-25 How to Test a Sensor Faucet in the Installed Basin Pilot a real pair of wash stations, count missed and unintended starts separately and keep the settings that produced the result. Read article](https://www.bestwaresoda.com/wiki/accept-sensor-faucets-in-the-installed-basin/)

Related to this article