# Replacing a Commercial Tap? Measure the Existing Counter First

Source: https://www.bestwaresoda.com/wiki/replace-water-fixtures-in-existing-counters/
Language: en-US

[Back to Water Wiki](https://www.bestwaresoda.com/wiki/)

Technology & Design

## Replacing a Commercial Tap? Measure the Existing Counter First

If your sink has a 22 mm hole, the diameter fits the AS112 cutout range. Check the cold supply, the mounting surface and the room underneath before ordering.

Revised 2026-11-24

People work beneath an open counter beside a water outlet

On this page

[Make a Sketch From Underneath](https://www.bestwaresoda.com/wiki/replace-water-fixtures-in-existing-counters/#section-1) [Will an AS112 Fit the Old Opening?](https://www.bestwaresoda.com/wiki/replace-water-fixtures-in-existing-counters/#section-2) [Approve the Tap and Tray Separately](https://www.bestwaresoda.com/wiki/replace-water-fixtures-in-existing-counters/#section-3) [What to Send With the Replacement Request](https://www.bestwaresoda.com/wiki/replace-water-fixtures-in-existing-counters/#section-4)

### Make a Sketch From Underneath

Before you order a replacement, take one photo from the working side and another from the cabinet. Include a ruler and show where the old faucet sits relative to the bowl and backsplash. Mark every hole you intend to reuse, its actual diameter, the distance between centers and the thickness the mounting hardware has to grip. If a backing plate stays in place, measure the full stack.

Look along the underside. Can a wrench reach the retaining nut? Can the hose reach the shutoff without folding against a divider? Can staff still shut off the water after the station goes back into service? Write down the supply fitting or thread. If the fixture hides the opening, measure the bare hole after shutting off the supply and removing the old fixture.

[\[1\]](https://www.bestwaresoda.com/wiki/replace-water-fixtures-in-existing-counters/#editorial-source-1) [\[3\]](https://www.bestwaresoda.com/wiki/replace-water-fixtures-in-existing-counters/#editorial-source-3) [\[4\]](https://www.bestwaresoda.com/wiki/replace-water-fixtures-in-existing-counters/#editorial-source-4)

### Will an AS112 Fit the Old Opening?

On the AS112 drawing, the installation hole is Ø21–23 mm. At 22 mm you can take the cutout size off your list of open questions once you know the edge is sound. The AS112 is a single-hole, deck-mounted pre-rinse faucet for cold water, with a SUS304 stainless steel body. Check that its base can sit flat, that the hose has a clear path and that the sprayer reaches the part of the bowl where staff rinse pans.

The supply changes your shortlist. When the station needs hot and cold water, bring up the mixer’s own drawing. Bestware’s ED200C uses one 32–35 mm hole, so a 22 mm opening needs an approved modification before you can fit it. The EH200C uses two holes. If a quotation specifies a different spray valve or hose, put those part numbers on the sketch so the installer reviews the assembly that will arrive.

[\[1\]](https://www.bestwaresoda.com/wiki/replace-water-fixtures-in-existing-counters/#editorial-source-1) [\[2\]](https://www.bestwaresoda.com/wiki/replace-water-fixtures-in-existing-counters/#editorial-source-2) [\[3\]](https://www.bestwaresoda.com/wiki/replace-water-fixtures-in-existing-counters/#editorial-source-3) [\[4\]](https://www.bestwaresoda.com/wiki/replace-water-fixtures-in-existing-counters/#editorial-source-4)

### Approve the Tap and Tray Separately

The same survey can expose a second issue when the job includes a drinks station. The G1DS-110/1010 and G1DS-123/1023 installation manuals give a maximum of 40 mm for the tap mounting surface and 36 mm for the drip tray. On a 38 mm counter the tap passes the thickness check. Put the tray where the finished mounting surface is 36 mm or less, or ask the supplier for a documented compatible mounting detail.

Trace where the tray will drain and check that you can reach the connection with the cabinet in place. If the new pipe meets a crossbar or the basin waste, ask the installer to mark the alternate route. Put a separate approval beside the tap and tray on the drawing.

[\[5\]](https://www.bestwaresoda.com/wiki/replace-water-fixtures-in-existing-counters/#editorial-source-5) [\[6\]](https://www.bestwaresoda.com/wiki/replace-water-fixtures-in-existing-counters/#editorial-source-6)

### What to Send With the Replacement Request

Send the measured cutout, total mounting thickness, a photo from below, the existing supply fitting and the market where the unit will be installed. State whether the job needs a replacement that reuses the hole or allows a larger cutout. Put those facts in the quote request so the installer can check the proposal before the station is shut down.

Open an AS112 fit-check request with those details

[\[2\]](https://www.bestwaresoda.com/wiki/replace-water-fixtures-in-existing-counters/#editorial-source-2) [\[3\]](https://www.bestwaresoda.com/wiki/replace-water-fixtures-in-existing-counters/#editorial-source-3)

### Sources for This Edition

1. [Bestware AS112 technical specifications](https://www.bestware-stainless.com/Products/Pre-Rinse-Faucets/American-Style/AS112) · Product Specifications and component options, including hole size, body, hose and valve model
2. [Bestware AS112 specification and dimensions](https://www.bestware-stainless.com/upload/filexk_flyers/AS112.pdf#page=1) · One-page AS112 product sheet, Attributes/Details and dimensioned drawing
3. [Bestware ED200C technical specifications](https://www.bestware-stainless.com/upload/filexk_flyers/ED200C.pdf#page=1) · Single-hole hot/cold mounting and Ø32–35 mm cutout
4. [Bestware EH200C technical specifications](https://www.bestware-stainless.com/Products/Pre-Rinse-Faucets/European-Style/EH200C) · Two-hole hot/cold mounting
5. [G1DS-110 / 1010 installation instructions](https://www.bestwaresoda.com/assets/documents/g1ds-110-g1ds-1010-installation-manual-2026-v1.1-en.pdf#page=10) · PDF page 10, countertop dispensers and drip tray installation dimensions
6. [G1DS-123 / 1023 installation instructions](https://www.bestwaresoda.com/assets/documents/g1ds-123-g1ds-1023-installation-manual-2026-v1.2-en.pdf#page=10) · PDF pages 10–11, countertop cutouts and thickness limits

### Specifications for Planning

Manufacturer rating

AS112 opening for the mounting hole

Ø21–23 mm

Single-hole, cold-water configuration. Verify the exact SKU against the existing deck and supplied drawing.

[Manufacturer document](https://www.bestware-stainless.com/Products/Pre-Rinse-Faucets/American-Style/AS112)

### Continue With These Decisions

- [How to Test a Commercial Pre-Rinse Spray Valve Before You Accept It](https://www.bestwaresoda.com/wiki/accept-pre-rinse-spray-valves/)
  
  Check the method and what to record.
- [Water Dispenser Installation and Handover: What to Sign Off](https://www.bestwaresoda.com/wiki/water-system-installation-and-handover/)
  
  Check the method and what to record.
- [How to Check a Water Equipment Certificate Before You Buy](https://www.bestwaresoda.com/wiki/read-certification-correctly/)
  
  Once the fixture fits, check that the listing names the exact model and covers your market.

### Continue Exploring

Related to this article

[Technology & Design 4 min read Updated 2026-11-25 Check the Finished Cabinet Before Your Water Dispenser Ships Get the drawing for the exact unit, then check the installed cabinet, power, water and drain against it. A 420 mm opening is wider than the chassis and narrower than the installation drawing requires. Read article](https://www.bestwaresoda.com/wiki/installation-power-and-cooling/)

Related to this article

[Technology & Design 3 min read Updated 2026-11-25 How to Plan a Remote Water Dispenser Line Trace the fitted route before you order the chiller. Then check the first glass after a quiet stretch and the next four at the tap. Read article](https://www.bestwaresoda.com/wiki/plan-remote-water-dispensing-lines/)

Related to this article

[Technology & Design 3 min read Updated 2026-11-25 How to Plan Drinking-Water Access at School Start with the places students need water during lunch, short breaks and sports. Then check the route, the time it takes to fill a bottle and the backup when an outlet is closed. Read article](https://www.bestwaresoda.com/wiki/plan-school-campus-water-access/)

Related to this article