# How to Read a Water Chiller’s Refrigerant Label

Source: https://www.bestwaresoda.com/wiki/reading-refrigerant-information/
Language: en-US

[Back to Water Wiki](https://www.bestwaresoda.com/wiki/)

Technology & Design

## How to Read a Water Chiller’s Refrigerant Label

Match the nameplate to the chilling unit you are buying. Record the refrigerant and factory charge, then use that exact configuration to check installation and service.

Revised 2026-11-24

Insulated pipes, fittings and a compressor inside an opened water appliance

On this page

[Photograph the Unit You’re Going to Own](https://www.bestwaresoda.com/wiki/reading-refrigerant-information/#section-1) [What 0.35–0.40 MPa Means on a Bestware Order](https://www.bestwaresoda.com/wiki/reading-refrigerant-information/#section-2) [Match the Market Document to the Exact Configuration](https://www.bestwaresoda.com/wiki/reading-refrigerant-information/#section-3) [Ask Separately About Energy Use and Service](https://www.bestwaresoda.com/wiki/reading-refrigerant-information/#section-4)

### Photograph the Unit You’re Going to Own

If a chiller arrives with a system brochure, take a clear photo of the actual chilling unit’s nameplate before it goes into the cabinet. Keep a second photo that shows where the plate is on the unit, along with any separate refrigerant or warning label. On a dispenser made up of several units, look for the plate on the cooling unit and record which part of the order it belongs to.

Copy the full model and suffix, serial number, electrical rating, refrigerant designation and factory charge exactly as printed. Keep the unit of mass with the charge. If the manufacturer identifies multiple refrigeration circuits, record the charge for each. If the nameplate and packing list use different model codes, ask the manufacturer for a written match before signing off the cooling unit’s refrigerant entry.

[\[1\]](https://www.bestwaresoda.com/wiki/reading-refrigerant-information/#editorial-source-1) [\[10\]](https://www.bestwaresoda.com/wiki/reading-refrigerant-information/#editorial-source-10)

### What 0.35–0.40 MPa Means on a Bestware Order

Take a sample Bestware G1DS-123 order specifying the 110 V / 60 Hz option. Its product page separates the chilling unit from the heating unit, and the installation manual gives 0.35–0.40 MPa in the sparkling-water commissioning section. Enter that range under beverage CO₂ supply. The working fluid in the refrigeration circuit has its own designation and factory charge. The public documents give no verified refrigerant or charge for this configuration, so leave that entry open for the delivered chilling unit’s label or its matching factory record.

R-290 is the designation for propane used as a refrigerant, with a flammable A3 safety classification. A label reading R-744 signals CO₂ in a refrigeration circuit. A separate beverage cylinder supplies food-grade CO₂ used to carbonate water. Keep its supplier and lot paperwork with the carbonation system.

[\[1\]](https://www.bestwaresoda.com/wiki/reading-refrigerant-information/#editorial-source-1) [\[2\]](https://www.bestwaresoda.com/wiki/reading-refrigerant-information/#editorial-source-2) [\[3\]](https://www.bestwaresoda.com/wiki/reading-refrigerant-information/#editorial-source-3) [\[12\]](https://www.bestwaresoda.com/wiki/reading-refrigerant-information/#editorial-source-12)

### Match the Market Document to the Exact Configuration

In the United States, EPA’s SNAP water cooler entry accepts R-290 in covered new equipment under specified use conditions. The current entry checked on November 24, 2026 limits the refrigerant charge to 60 g per circuit and sets design and marking conditions, including the requirements of Supplement SB of the seventh edition of UL 399. A proposed update discusses 130 g per circuit in a newer edition of UL 399. Ask for the equipment’s end-use category and the documentation for the supplied model. The number you enter for the delivered machine comes from its plate or matching factory record.

For equipment within the EU fluorinated gas labelling rules, the label also gives refrigerant weight, CO₂ equivalent and GWP. R-290 is a hydrocarbon. Equipment using only R-290 falls outside that particular F-gas label requirement. Check flammability markings, the applicable equipment paperwork and the service provider’s scope separately.

[Check which models a certificate actually covers](https://www.bestwaresoda.com/wiki/read-certification-correctly/)

[\[4\]](https://www.bestwaresoda.com/wiki/reading-refrigerant-information/#editorial-source-4) [\[5\]](https://www.bestwaresoda.com/wiki/reading-refrigerant-information/#editorial-source-5) [\[6\]](https://www.bestwaresoda.com/wiki/reading-refrigerant-information/#editorial-source-6) [\[7\]](https://www.bestwaresoda.com/wiki/reading-refrigerant-information/#editorial-source-7) [\[8\]](https://www.bestwaresoda.com/wiki/reading-refrigerant-information/#editorial-source-8) [\[10\]](https://www.bestwaresoda.com/wiki/reading-refrigerant-information/#editorial-source-10)

### Ask Separately About Energy Use and Service

If you are comparing running costs, ask for measured energy over the same time period with comparable inlet-water temperature, room temperature, water settings and serving schedule. Record idle energy and energy during service separately where the supplier reports them. A low GWP describes the refrigerant’s climate effect on a defined basis. Electricity use and any refrigerant released over the machine’s life still affect the overall comparison.

Before closing the receiving record, file the manual revision, confirm the cabinet and ventilation for the actual unit and get the local service provider’s name and scope in writing. If identification is still open, leave that part of the handover pending and note the specific photo or document the supplier owes you.

[Check cabinet ventilation with the installation drawing](https://www.bestwaresoda.com/wiki/cooling-airflow-checks/)

[\[9\]](https://www.bestwaresoda.com/wiki/reading-refrigerant-information/#editorial-source-9) [\[3\]](https://www.bestwaresoda.com/wiki/reading-refrigerant-information/#editorial-source-3) [\[8\]](https://www.bestwaresoda.com/wiki/reading-refrigerant-information/#editorial-source-8) [\[11\]](https://www.bestwaresoda.com/wiki/reading-refrigerant-information/#editorial-source-11)

### Sources for This Edition

1. [Bestware G1DS-123 · Chilling Unit and Heating Unit](https://www.bestware-sparkling.com/Products/Commercial-Sparkling-Water-Dispensers/4-in-1/G1DS-123) · Manufacturer specification, Chilling Unit and Heating Unit tables. The chilling unit has 110 V / 60 Hz and 220 V / 50 Hz supply options and a 40 L/h chilling capacity rating. The public table gives beverage CO₂ data. Factory refrigerant identity and charge are to be checked on the delivered unit.
2. [Bestware G1DS-123 / G1DS-1023 Installation Manual V1.2](https://www.bestwaresoda.com/assets/documents/g1ds-123-g1ds-1023-installation-manual-2026-v1.2-en.pdf#page=16) · PDF p. 16, initial sparkling water commissioning, steps 2.1 and 5.2. The 0.35–0.40 MPa range belongs to the separate beverage CO₂ supply and is a pressure.
3. [ASHRAE Handbook · Halocarbon and Hydrocarbon Refrigeration Systems](https://handbook.ashrae.org/handbooks/R26/IP/r26_ch01/r26_ch01_ip.aspx) · Chapter 1, Properties of Refrigerants and Table 2. R-290 is propane, safety group A3. R-744 is the designation for CO₂ when used as a refrigerant. The GWP comparison specifies a 100-year basis and distinguishes assessment editions.
4. [US EPA · SNAP Listing for Substitutes in Water Coolers](https://www.epa.gov/snap/substitutes-water-coolers) · R-290 row, acceptable with use conditions for new equipment. EPA notes that other program restrictions may apply.
5. [40 CFR 82 Subpart G Appendix V · Water Coolers (New Only)](https://www.ecfr.gov/current/title-40/chapter-I/subchapter-C/part-82/subpart-G/appendix-Appendix%20V%20to%20Subpart%20G%20of%20Part%2082) · Table entry 5 in the current text checked on Nov. 24, 2026. For covered new water coolers designed and identified for R-290, the use conditions include UL 399 Supplement SB, up to 60 g per refrigerant circuit and flammable-refrigerant markings. The entry also describes training for service personnel.
6. [US EPA · Proposed SNAP Rule 27, Federal Register](https://www.govinfo.gov/content/pkg/FR-2025-11-10/pdf/2025-19812.pdf#page=25) · Nov. 10, 2025 proposed rule, section VI.E.4, PDF p. 25. It discusses 130 g per circuit in the eighth edition of UL 399 and proposes changes for new water coolers. The EPA rule index still showed the water-cooler change as proposed when checked on Nov. 24, 2026.
7. [Regulation (EU) 2024/573 · Article 12](https://eur-lex.europa.eu/eli/reg/2024/573/2024-02-20/eng/) · Article 12(1)(a), (3) and (4) applies to in-scope refrigeration equipment containing or relying on fluorinated greenhouse gases. It specifies gas identity, weight, CO₂ equivalent, GWP, and where applicable sealed-equipment wording, as well as the location and language of the label.
8. [Implementing Regulation (EU) 2024/2215 · Service Certification Scope](https://eur-lex.europa.eu/eli/reg_impl/2024/2215/oj/eng) · Articles 1–4 define covered equipment, activities, and certification for natural and legal persons. Certain activities involving alternatives such as hydrocarbons are covered separately from product labelling.
9. [ENERGY STAR · Water Coolers Version 3.0](https://www.energystar.gov/products/water_coolers) · Key product criteria distinguish energy in On Mode with No Water Draw from performance with water draw. Used here to explain different test conditions, without claiming qualification or ratings for either Bestware model.
10. [Bestware · Verify Certificate Coverage](https://www.bestwaresoda.com/wiki/read-certification-correctly/) · Internal purchasing guide to issuer records, exact model coverage and distinctions between whole equipment and component evidence.
11. [Bestware · Cabinet Airflow and Installation Checks](https://www.bestwaresoda.com/wiki/cooling-airflow-checks/) · Internal field guide to cabinet air paths, approved drawings and performance checks at handover.
12. [Bestware · Check Beverage CO₂ at Delivery](https://www.bestwaresoda.com/wiki/specify-beverage-carbon-dioxide/) · Internal receiving guide for the separate food-grade CO₂ supply and its supplier and lot records.

### Continue With These Decisions

- [How to Measure a Commercial Water Dispenser’s Energy Use](https://www.bestwaresoda.com/wiki/measure-dispenser-energy-use/)
  
  Measure the installed equipment through standby, service and first-cup recovery.
- [Water Dispenser Installation and Handover: What to Sign Off](https://www.bestwaresoda.com/wiki/water-system-installation-and-handover/)
  
  Record the delivered unit, cabinet conditions and open items at handover.

### Continue Exploring

Related to this article

[Technology & Design 3 min read Updated 2026-11-25 How to Check Hot-Water Power, Energy and Recovery Use the heater rating to plan the connection. Use measured kWh and a timed run of hot-water draws to see what the dispenser can actually deliver during a shift. Read article](https://www.bestwaresoda.com/wiki/hot-water-power-load-and-operating-hours/)

Related to this article

[Technology & Design 4 min read Updated 2026-11-25 Check the Finished Cabinet Before Your Water Dispenser Ships Get the drawing for the exact unit, then check the installed cabinet, power, water and drain against it. A 420 mm opening is wider than the chassis and narrower than the installation drawing requires. Read article](https://www.bestwaresoda.com/wiki/installation-power-and-cooling/)

Related to this article

[Technology & Design 3 min read Updated 2026-11-25 How to Plan a Remote Water Dispenser Line Trace the fitted route before you order the chiller. Then check the first glass after a quiet stretch and the next four at the tap. Read article](https://www.bestwaresoda.com/wiki/plan-remote-water-dispensing-lines/)

Related to this article