# Does a Point-of-Use Water Filter Need NSF 61?

Source: https://www.bestwaresoda.com/wiki/nsf-point-of-use-scope/
Language: en-US

[Back to Water Wiki](https://www.bestwaresoda.com/wiki/)

Water & Science

## Does a Point-of-Use Water Filter Need NSF 61?

Read the actual NSF 42, 53 and 58 claims before approving a filter and its replacement cartridge. Check separately ordered taps and valves against the project requirements.

Revised 2026-11-25

People review a product catalogue and documents at a Bestware exhibition display

On this page

[For the Filter, Start With the Treatment Listing](https://www.bestwaresoda.com/wiki/nsf-point-of-use-scope/#section-1) [What a 42 Listing and a 53 Listing Can Say About the Same Filter](https://www.bestwaresoda.com/wiki/nsf-point-of-use-scope/#section-2) [With Reverse Osmosis, Read Past the Number 58](https://www.bestwaresoda.com/wiki/nsf-point-of-use-scope/#section-3) [How to Read a Quote for a Dispenser With Separate RO](https://www.bestwaresoda.com/wiki/nsf-point-of-use-scope/#section-4) [What to Save With the Order](https://www.bestwaresoda.com/wiki/nsf-point-of-use-scope/#section-5)

### For the Filter, Start With the Treatment Listing

A point-of-use (POU) filter certified under NSF/ANSI 42, 53 or 58 can have the required materials testing without a separate NSF/ANSI/CAN 61 listing for that treatment unit. Those standards include materials requirements for the POU application and require the lead-content limits of NSF/ANSI/CAN 372. If you are buying a separate tap, valve or fitting, ask which requirements apply to that item and check its own documentation.

First locate the proposed treatment. A filter serving a single bar outlet is point-of-use. A system treating the incoming supply to a building is point-of-entry (POE). NSF explains that the POE applications covered by standards such as 42 and 53 have to meet 61. On a quote that says only “NSF 42,” ask how the listed model is intended to be installed.

[\[1\]](https://www.bestwaresoda.com/wiki/nsf-point-of-use-scope/#editorial-source-1) [\[2\]](https://www.bestwaresoda.com/wiki/nsf-point-of-use-scope/#editorial-source-2)

### What a 42 Listing and a 53 Listing Can Say About the Same Filter

Open NSF’s public entry for faucet-mounted model PFM350V and follow the row for replacement element RF-9999. In the 42 table, the claims include chlorine, taste and odor, and nominal Class I particulate reduction. Now scroll to 53. The same model and replacement element have a separate Lead Reduction claim there. If a purchase specification names lead, copy the 53 claim and the replacement code into the order record. Keep the taste and odor claim on its own line.

The model page also shows a rated service cycle with a footnote excluding mechanical filtration from that capacity claim. Work from the full row and its notes when planning cartridge changes. A service-cycle figure loses an important condition when it is copied out of the table on its own.

[\[3\]](https://www.bestwaresoda.com/wiki/nsf-point-of-use-scope/#editorial-source-3)

### With Reverse Osmosis, Read Past the Number 58

Under NSF/ANSI 58, reduction of total dissolved solids (TDS) is a required claim. A claim for lead reduction is optional. The public 58 row for RO10DX identifies module FLTMEME100 and lists TDS Reduction. The \[Pb\] note says that the product meets the weighted lead-content threshold of 0.25% or less. That percentage describes the wetted materials. To approve a lead-reduction requirement for drinking water, find Lead Reduction in the applicable treatment listing for the offered model.

[\[4\]](https://www.bestwaresoda.com/wiki/nsf-point-of-use-scope/#editorial-source-4) [\[5\]](https://www.bestwaresoda.com/wiki/nsf-point-of-use-scope/#editorial-source-5) [\[6\]](https://www.bestwaresoda.com/wiki/nsf-point-of-use-scope/#editorial-source-6)

### How to Read a Quote for a Dispenser With Separate RO

Bestware’s G1DS-1023 is an undercounter dispenser offered with a standalone reverse-osmosis unit. On a quote for that setup, put the dispenser, the RO unit and replacement module, and any separately ordered outlet tap or valve on separate lines. Ask for the RO manufacturer and full module code before checking a treatment listing. The public model page identifies the arrangement. A claim about the specific module’s treatment still needs its matching entry. Our NSF directory search under G1DS-1023 produced no match.

An NSF/ANSI/CAN 61 listing, when required, concerns health effects from substances the listed materials can impart to drinking water. For example, Bestware publishes the first of three pages for IAPMO file N-12529, which names 61-2022. On November 24, the IAPMO file search returned no entry for 12529. Leave that record open for current status and the covered model schedule. Use the quoted part number to narrow the request.

[\[7\]](https://www.bestwaresoda.com/wiki/nsf-point-of-use-scope/#editorial-source-7) [\[8\]](https://www.bestwaresoda.com/wiki/nsf-point-of-use-scope/#editorial-source-8) [\[2\]](https://www.bestwaresoda.com/wiki/nsf-point-of-use-scope/#editorial-source-2) [\[1\]](https://www.bestwaresoda.com/wiki/nsf-point-of-use-scope/#editorial-source-1) [\[10\]](https://www.bestwaresoda.com/wiki/nsf-point-of-use-scope/#editorial-source-10) [\[9\]](https://www.bestwaresoda.com/wiki/nsf-point-of-use-scope/#editorial-source-9)

### What to Save With the Order

Record the use, full listed model, replacement part, issuer, check date and exact claim. Save any conditions that affect how the equipment will be installed or serviced. A treatment entry that shows TDS reduction can close that line of the review. If the project also asks for lead reduction or documentation for a separate tap, keep those lines open until the matching records arrive.

[Check the listing and match the quoted model](https://www.bestwaresoda.com/wiki/read-certification-correctly/)

[\[4\]](https://www.bestwaresoda.com/wiki/nsf-point-of-use-scope/#editorial-source-4) [\[2\]](https://www.bestwaresoda.com/wiki/nsf-point-of-use-scope/#editorial-source-2) [\[11\]](https://www.bestwaresoda.com/wiki/nsf-point-of-use-scope/#editorial-source-11)

### Sources for This Edition

1. [NSF, March 30, 2026 · How NSF/ANSI/CAN 61 Applies to Water Treatment Devices](https://www.nsf.org/knowledge-library/what-nsf-standards-reference-nsf-ansi-can-61-and-what-does-it-mean) · Sections on Point-of-Use (POU) and Point-of-Entry (POE) water treatment. For the specified POU standards, including 42, 53 and 58, materials are evaluated under the applicable treatment standard and the lead-content limits of 372 apply. For the POE standards NSF names, including 42 and 53, 61 applies.
2. [NSF · Certified Components and End Products](https://www.nsf.org/knowledge-library/certified-components-end-products-water-industry) · Parts and assemblies have distinct certification scopes. An individually certified component does not certify the end product; a certified end product does not give an internal part its own stand-alone certification.
3. [NSF Product and Service Listings · PFM350V With RF-9999](https://info.nsf.org/Certified/DWTU/Listings.asp?TradeName=PUR+PFM350V&hdModlStd=ModlStd) · Read the exact PFM350V row with RF-9999 under each standard. 42 shows chlorine, taste and odor, and nominal particulate Class I. 53 separately shows Lead Reduction. The directory excludes mechanical filtration from its service-cycle capacity claim footnote.
4. [NSF · NSF/ANSI 58 for Reverse Osmosis Drinking Water Treatment Systems](https://www.nsf.org/knowledge-library/nsf-ansi-58-reverse-osmosis-drinking-water-treatment-systems) · Requirements and Claims sections. Total dissolved solids reduction is required under 58. Lead and several other contaminant-reduction claims are optional, with the actual certification scope shown in the listing.
5. [NSF Product and Service Listings · RO10DX Under NSF/ANSI 58](https://info.nsf.org/Certified/DWTU/Listings.asp?Company=C0393493&Standard=058) · RO10DX, plumbed in to a separate tap, replacement module FLTMEME100. The row lists TDS Reduction. Its \[Pb\] note describes weighted average lead content at or below 0.25%. RO5DX is a separate row with its own replacement module.
6. [US EPA · Final Lead Free Rule, Questions and Answers](https://www.epa.gov/sdwa/questions-and-answers-about-final-lead-free-rule) · Definition of lead free under the US Safe Drinking Water Act. The 0.25% figure is a weighted average across wetted surfaces of covered plumbing items.
7. [Bestware G1DS-1023 · Standalone RO Configuration](https://www.bestware-sparkling.com/Products/Commercial-Sparkling-Water-Dispensers/4-in-1/G1DS-1023) · Product name and technical details. The G1DS-1023 is an undercounter dispenser with standalone RO filtration. Filtration specifications describe RO and PAC. Verify the independent module's exact identification, replacement parts and directory claims on the offered bill of materials.
8. [NSF · Drinking Water Treatment Unit Directory](https://info.nsf.org/Certified/DWTU/) · Search by company or exact model. The November 24–25, 2026 directory checks produced no matching product for Bestware or the queried codes G1DS-110, G1DS-123, G1DS-1023 and G1DSA-1. The check is limited to this directory and these search terms.
9. [IAPMO R&T · Product Listing Directory](https://pld.iapmo.org/) · November 24–25, 2026 directory checks. File Numbers 12529 and N-12529 returned no entries. The listee search returned active files 12528 for plumbing fixture fittings and 12530 for lead content.
10. [Bestware · Published IAPMO N-12529 Cover, Page 1 of 3](https://www.bestware-stainless.com/upload/imgxk_certifications/N-12529_7-17-2025_Certificate%EF%BC%88NSF%E8%AF%81%E4%B9%A6%EF%BC%8C2030%E5%B9%B46%E6%9C%88%E5%88%B0%E6%9C%9F%EF%BC%89.webp) · Publisher's image of page 1 of 3. IAPMO R&T file N-12529, NSF/ANSI/CAN 61-2022, drinking-water system components, and printed footnote that the certificate is not evidence of a current listing.
11. [Bestware · Verify an Equipment Listing Before Buying](https://www.bestwaresoda.com/wiki/read-certification-correctly/) · Same-language check for the issuer, current record, listed family and exact configuration, with 12528 and 12530 as separate files.
12. [Bestware · Identify Replacement Cartridges and Consumables](https://www.bestwaresoda.com/wiki/water-system-consumables/) · Same-language guide for recording the replacement part number and the service cycle when approving interchangeable stock.

### Continue With These Decisions

- [How to Choose a Water Filter for a Drinks Counter](https://www.bestwaresoda.com/wiki/selecting-water-filter-functions/)
  
  Define the treatment job and the flow your site needs before selecting the filter.
- [How to Verify a Filter’s NSF Protocol 549 Claim for Glyphosate Reduction](https://www.bestwaresoda.com/journal/nsf-p549-glyphosate-claims/)
  
  Check the assigned protocol for a specific glyphosate reduction claim.

### Continue Exploring

Related to this article

[Water & Science 3 min read Updated 2026-11-25 How to Compare Microfiltration, Ultrafiltration, Nanofiltration and Reverse Osmosis Start with what the water needs to lose or retain. Then compare the production of the complete system under the same conditions, and check what reaches the tap. Read article](https://www.bestwaresoda.com/wiki/comparing-membrane-filtration/)

Related to this article

[Water & Science 6 min read Updated 2026-11-25 How to Choose a Water Filter for a Drinks Counter Start with the inlet water and the job at the counter. A single cartridge may be enough, provided the fitted system still delivers the water you need at peak service. Read article](https://www.bestwaresoda.com/wiki/selecting-water-filter-functions/)

Related to this article

[Water & Science 4 min read Source date 2026-10-14 How to Verify a Filter’s NSF Protocol 549 Claim for Glyphosate Reduction NSF released a way to verify a specific filter claim on October 14, 2026. A purchase still comes down to the listed model, the cartridge in the quote, and what the certification actually covers. Read article](https://www.bestwaresoda.com/journal/nsf-p549-glyphosate-claims/)

Related to this article