# How to Check a Preset Pour for Consistent Portions

Source: https://www.bestwaresoda.com/wiki/measured-dispensing-for-consistent-portions/
Language: en-US

[Back to Water Wiki](https://www.bestwaresoda.com/wiki/)

Technology & Design

## How to Check a Preset Pour for Consistent Portions

Find out what stops the pour, then measure each serving in grams or milliliters through a run and after a pause.

Revised 2026-11-24

Round dispenser control showing a two-second countdown and a Press to stop message

On this page

[An Average of 200 G Can Hide Two Failed Pours](https://www.bestwaresoda.com/wiki/measured-dispensing-for-consistent-portions/#section-1) [Find out What Makes the Tap Stop](https://www.bestwaresoda.com/wiki/measured-dispensing-for-consistent-portions/#section-2) [Choose the Scale or the Graduated Measure](https://www.bestwaresoda.com/wiki/measured-dispensing-for-consistent-portions/#section-3) [Keep the Opening Pour and the Next Run Separate](https://www.bestwaresoda.com/wiki/measured-dispensing-for-consistent-portions/#section-4) [Use the Checked Volume on the Service Plan](https://www.bestwaresoda.com/wiki/measured-dispensing-for-consistent-portions/#section-5)

### An Average of 200 G Can Hide Two Failed Pours

Say your bar wants 200 g of plain sparkling water per glass, with a range of 196–204 g for each serving. Five sample readings are 194, 199, 200, 201 and 206 g. The average is exactly 200 g. Only three pours pass, and the gap between the lightest and heaviest is 12 g. Ask to see the individual readings before accepting a supplier’s demonstration. Measure the amount the customer would receive, with ice and syrup left out if the test is for the water alone.

[\[8\]](https://www.bestwaresoda.com/wiki/measured-dispensing-for-consistent-portions/#editorial-source-8) [\[7\]](https://www.bestwaresoda.com/wiki/measured-dispensing-for-consistent-portions/#editorial-source-7)

### Find out What Makes the Tap Stop

Ask the supplier what the preset controls on the unit you are buying. The Bestware G1DS-110 and G1DS-123 manuals specify a separate timer from 1 to 60 seconds for each water mode. They show a countdown, manual stop and memory after a power-off. Set a time, then measure the amount it actually delivers in that mode. If the average flow differs from one pour to the next, the same setting can give a different amount.

If the quote says the machine meters a volume, ask what measures it and for the conditions behind the claim. Get the target, the allowed difference per pour and the water types covered in writing. You can use the same test sheet while recording the relevant setting for each kind of control.

[\[1\]](https://www.bestwaresoda.com/wiki/measured-dispensing-for-consistent-portions/#editorial-source-1) [\[2\]](https://www.bestwaresoda.com/wiki/measured-dispensing-for-consistent-portions/#editorial-source-2) [\[3\]](https://www.bestwaresoda.com/wiki/measured-dispensing-for-consistent-portions/#editorial-source-3)

### Choose the Scale or the Graduated Measure

If the recipe is in grams, choose a scale with capacity for the filled cup and enough resolution for the agreed band. Set a dry cup on the level scale and tare it, or subtract that cup’s empty weight from the filled weight. Check zero and verify the scale near the combined load of cup and drink before the run. Keep the cup exterior dry and record the net reading at the agreed time after the pour.

If the order calls for milliliters, use a suitable clear graduated vessel. For sparkling water, agree on a reading time that allows the foam to settle enough to see the liquid. If it still obscures the level, record that and repeat the series at a shared later reading time. Read the bottom of a clear concave meniscus with your eyes level. NIST’s laboratory instructions explain that technique and the role of liquid density in a mass-to-volume conversion. For a volume target at the bar, reading the actual liquid avoids having to estimate density.

[\[4\]](https://www.bestwaresoda.com/wiki/measured-dispensing-for-consistent-portions/#editorial-source-4) [\[5\]](https://www.bestwaresoda.com/wiki/measured-dispensing-for-consistent-portions/#editorial-source-5) [\[6\]](https://www.bestwaresoda.com/wiki/measured-dispensing-for-consistent-portions/#editorial-source-6)

### Keep the Opening Pour and the Next Run Separate

Label the sheet with the unit, water mode, timer setting, measuring instrument and the temperature of the pour. Start the baseline when the equipment indicates cooling is ready, then measure outlet temperature as well. If service starts sooner in practice, give that startup its own set of readings. Have one operator work through consecutive pours with the same setup, then take a first pour after the pause the bar normally has between orders.

Test the first full pour after a manual stop in its own row. When two outlets share a feed, run another series with both operating. Keep chilled still and sparkling in separate groups. Once a result is outside the band, confirm the measuring method and actual conditions before changing an authorized setting. Keep the earlier sheet and rerun the affected groups after a filter change, a supply change or a setting adjustment.

[Plan the first-pour, consecutive-pour and recovery checks](https://www.bestwaresoda.com/wiki/plan-water-equipment-pilot-acceptance/)

[\[7\]](https://www.bestwaresoda.com/wiki/measured-dispensing-for-consistent-portions/#editorial-source-7) [\[1\]](https://www.bestwaresoda.com/wiki/measured-dispensing-for-consistent-portions/#editorial-source-1) [\[2\]](https://www.bestwaresoda.com/wiki/measured-dispensing-for-consistent-portions/#editorial-source-2) [\[9\]](https://www.bestwaresoda.com/wiki/measured-dispensing-for-consistent-portions/#editorial-source-9)

### Use the Checked Volume on the Service Plan

Once you have a volume from the graduated measure, use that figure for a demand estimate based on actual orders. Log extra water for top-ups, discarded pours and cleaning separately so the test tells you how much comes out and the service plan tells you what guests are served.

[Estimate restaurant demand using your measured serving volume](https://www.bestwaresoda.com/planning/restaurant-water-capacity/)

[\[10\]](https://www.bestwaresoda.com/wiki/measured-dispensing-for-consistent-portions/#editorial-source-10) [\[4\]](https://www.bestwaresoda.com/wiki/measured-dispensing-for-consistent-portions/#editorial-source-4)

### Sources for This Edition

1. [Bestware G1DS-110 / G1DS-1010 Installation and User Manual, 2026 V1.1](https://www.bestwaresoda.com/assets/documents/g1ds-110-g1ds-1010-installation-manual-2026-v1.1-en.pdf#page=3) · Physical PDF page 3, printed pages 01–02, Dispenser Tap Operation Instructions and Setting Dispensing Time. Separate 1–60-second settings per water mode, power-off memory, countdown and manual stop. Physical page 4 explains cooling indications. The documented preset is time.
2. [Bestware G1DS-123 / G1DS-1023 Installation and User Manual, 2026 V1.2](https://www.bestwaresoda.com/assets/documents/g1ds-123-g1ds-1023-installation-manual-2026-v1.2-en.pdf#page=3) · Physical PDF page 3, printed pages 01–02. The tap has a countdown and manual stop, and stores a separate 1–60-second setting for each water mode after power-off. Physical page 4 describes the chilling-unit indications. No measured-portion accuracy is specified there.
3. [OpenStax College Physics 2e — Flow Rate and Its Relation to Velocity](https://openstax.org/books/college-physics-2e/pages/12-1-flow-rate-and-its-relation-to-velocity) · Section 12.1, Equation 12.1. Average volumetric flow is the volume passing over the elapsed time. Equal timed settings can yield different volumes if actual average flow changes.
4. [NIST GMP 3 (2019) — Reading a Meniscus With Water or Other Wetting Liquid](https://www.nist.gov/system/files/documents/2019/05/14/gmp-3-reading-meniscus-20190507.pdf) · Sections 1 and 3. In a volumetric instrument used with a stable concave meniscus, use the lowest point and control parallax. The original explains laboratory volumetric measurement techniques.
5. [NIST GMP 10 (2019) — Understanding Factors Affecting Weighing Operations](https://www.nist.gov/system/files/documents/2019/05/14/gmp-10-weighing-operation-factors-20190506.pdf) · Section on balance exercising and the surrounding weighing factors. The laboratory practice observes initial repeatability with a representative load and considers instrument conditions and operation. The article uses these measurement principles to describe preparation of a shop check.
6. [NIST SOP 14 (2019) — Gravimetric Calibration of Volumetric Standards](https://www.nist.gov/system/files/documents/2019/05/14/sop-14-gravimetric-calibration-20190508.pdf) · Section 3.6, water density. The laboratory conversion uses water density under specified conditions. It supplies the rationale for keeping net mass and directly measured volume separate in a field check.
7. JCGM 200:2012 — International Vocabulary of Metrology, §§ 2.15, 2.20–2.21 · Measurement precision and repeatability. Repeatability uses the same procedure, operator, measuring system, conditions and location over a short interval. A change of water mode or cooling stage belongs in a separate test group.
8. Five Sparkling Water Portions — Worked Net-Mass Example · Assumed buyer target 200 g net, 196–204 g inclusive, for sparkling water alone. Readings 194, 199, 200, 201 and 206 g sum to 1,000 g and average 200 g. Range is 12 g, and three of five meet the sample limits. Example only.
9. [Bestware — Commercial Water Dispenser Pilot and Acceptance Test](https://www.bestwaresoda.com/wiki/plan-water-equipment-pilot-acceptance/) · Same-language worksheet for first pours, consecutive service, recovery and acceptance.
10. [Bestware — Restaurant Water Capacity Calculator](https://www.bestwaresoda.com/planning/restaurant-water-capacity/) · Use measured liquid volume with orders and the busy period to estimate water demand. Keep failed pours and cleaning on a separate usage record.

### Continue With These Decisions

- [How to Match a Sparkling Water Tap to Your Bottles and Glasses](https://www.bestwaresoda.com/wiki/matching-dispensing-flow-and-containers/)
  
  Test the served volume again with the tall bottle and the short glass.
- [How to Measure a Commercial Water Dispenser’s Energy Use](https://www.bestwaresoda.com/wiki/measure-dispenser-energy-use/)
  
  Track metered electricity per liter that meets the service specification.

### Continue Exploring

Related to this article

[Technology & Design 3 min read Updated 2026-11-25 How to Compare Water Dispenser Noise Compare the same sound measurement in the same operating state, then listen at the nearest desk or table while the installed dispenser works. Read article](https://www.bestwaresoda.com/wiki/comparing-dispenser-noise/)

Related to this article

[Technology & Design 4 min read Updated 2026-11-25 How to Specify a Sparkling-Water Bottling Line for a Full Shift Put a counter at the end of the line. Define the drink, bottle and case, then agree what to count after cleaning, changeovers and product checks. Read article](https://www.bestwaresoda.com/wiki/specify-a-sparkling-water-bottling-line/)

Related to this article

[Technology & Design 3 min read Updated 2026-11-25 Which Liquids Can Go in a Soda Maker? If your model calls for plain water, add flavor in the glass. Before carbonating juice or tea directly, check what the exact model and bottle are designed to handle. Read article](https://www.bestwaresoda.com/wiki/approved-liquids-for-carbonation/)

Related to this article
