# How to Plan and Check Airflow in a Water Chiller Cabinet

Source: https://www.bestwaresoda.com/wiki/cooling-airflow-checks/
Language: en-US

[Back to Water Wiki](https://www.bestwaresoda.com/wiki/)

Technology & Design

## How to Plan and Check Airflow in a Water Chiller Cabinet

Size the cabinet for the full order, line up the exhaust with the door grille and run the agreed serving test with the finished cabinet closed.

Revised 2026-11-24

A technician works beside a water unit with twin front ventilation grilles beneath a counter

On this page

[Put the Equipment List Beside the Cabinet Drawing](https://www.bestwaresoda.com/wiki/cooling-airflow-checks/#section-1) [Follow the Heat to the Door](https://www.bestwaresoda.com/wiki/cooling-airflow-checks/#section-2) [Give the Cabinet Shop Two Sets of Dimensions](https://www.bestwaresoda.com/wiki/cooling-airflow-checks/#section-3) [Run the Serving Test With the Cabinet Closed](https://www.bestwaresoda.com/wiki/cooling-airflow-checks/#section-4) [Make the Cabinet Easy to Recheck Later](https://www.bestwaresoda.com/wiki/cooling-airflow-checks/#section-5)

### Put the Equipment List Beside the Cabinet Drawing

Before anyone cuts the cabinet, list what will live under the counter. Show the chiller, separate heater if fitted, filtration, hoses, valves and anything the staff will store there. Mark out the clear space between the finished panels, through the door opening and around its hinges. That gives the cabinet shop a drawing it can use and the installer a route to the water connections and service points.

Bestware lists a minimum base cabinet of 425 × 500 × 630 mm (W × D × H) for the integrated G1DS-110. The G1DS-123 drawing labels the same width, depth and height for its chilling unit alone. The G1DS-123 has a separate heater, and its product page lists 810 × 500 × 630 mm for the base cabinet for the units without reverse osmosis. The G1DS-1023 with standalone reverse osmosis is listed at 990 × 500 × 630 mm. Use the dimensions for the ordered configuration and check the actual layout with the supplier.

[\[1\]](https://www.bestwaresoda.com/wiki/cooling-airflow-checks/#editorial-source-1) [\[2\]](https://www.bestwaresoda.com/wiki/cooling-airflow-checks/#editorial-source-2) [\[3\]](https://www.bestwaresoda.com/wiki/cooling-airflow-checks/#editorial-source-3) [\[4\]](https://www.bestwaresoda.com/wiki/cooling-airflow-checks/#editorial-source-4) [\[6\]](https://www.bestwaresoda.com/wiki/cooling-airflow-checks/#editorial-source-6)

### Follow the Heat to the Door

A chiller moves heat out of the water and releases it to the surroundings. Trace how room air reaches the machine and where the warm discharge can leave. Pay extra attention around the door and adjacent compartments. A partition, a hose bundle or a stack of supplies can redirect warm air back toward the intake.

For the G1DS-110 integrated unit and G1DS-123 chilling unit, the placement drawings show 35 mm of clear space at each side intake and warm air leaving the front. The G1DS-110 V1.1 manual labels the front fan opening as an inlet in one sketch on PDF page 9. The airflow arrows, the fault diagram and the page 10 door drawing identify it as the outlet. Locate the outlet on the delivered machine and use a confirmed drawing to set out the lower grille before drilling or cutting.

[\[10\]](https://www.bestwaresoda.com/wiki/cooling-airflow-checks/#editorial-source-10) [\[4\]](https://www.bestwaresoda.com/wiki/cooling-airflow-checks/#editorial-source-4) [\[8\]](https://www.bestwaresoda.com/wiki/cooling-airflow-checks/#editorial-source-8) [\[5\]](https://www.bestwaresoda.com/wiki/cooling-airflow-checks/#editorial-source-5) [\[6\]](https://www.bestwaresoda.com/wiki/cooling-airflow-checks/#editorial-source-6) [\[7\]](https://www.bestwaresoda.com/wiki/cooling-airflow-checks/#editorial-source-7)

### Give the Cabinet Shop Two Sets of Dimensions

Both manuals show an upper door opening A of 269 × 35 mm for a grille installation size of 268 × 34.5 mm. They show a lower door opening B of 269 × 139 mm for a grille installation size of 268 × 138 mm. Set B opposite the machine exhaust. Keep clearance around the side intakes when laying out the door, plumbing and storage.

Mark the door cuts and the grille fitting sizes separately. Louvers and screens reduce the area actually available for air and can change resistance. If the shop proposes a different grille or adds mesh, ask for its free area and have the supplier confirm the airflow arrangement.

[\[5\]](https://www.bestwaresoda.com/wiki/cooling-airflow-checks/#editorial-source-5) [\[7\]](https://www.bestwaresoda.com/wiki/cooling-airflow-checks/#editorial-source-7) [\[11\]](https://www.bestwaresoda.com/wiki/cooling-airflow-checks/#editorial-source-11)

### Run the Serving Test With the Cabinet Closed

Fit the door and trim and leave the plumbing and stored supplies in their usual positions. Agree the serving sequence and acceptable outlet temperature with the supplier before testing. Record room temperature, air temperature at the intake, inlet-water temperature, serving volume and time between pours. Take outlet temperature readings through the run. After the run, record how long the machine takes to meet the agreed serving condition again.

If cooling is poor, start by checking the side intakes and the path out of the cabinet. The manuals list those checks and direct suspected fan faults to service. Note the readings and any error code while the setup is still in place.

[\[8\]](https://www.bestwaresoda.com/wiki/cooling-airflow-checks/#editorial-source-8) [\[9\]](https://www.bestwaresoda.com/wiki/cooling-airflow-checks/#editorial-source-9) [\[10\]](https://www.bestwaresoda.com/wiki/cooling-airflow-checks/#editorial-source-10)

### Make the Cabinet Easy to Recheck Later

With the door swung open, check that a technician can reach the grilles for cleaning and withdraw the equipment for service. On the G1DS-123, include access to the left-side power switch on the separate heater. Give the operator the as-built drawing, grille reference and completed test sheet. If a door, grille, appliance or storage layout changes, repeat the affected checks on the revised cabinet.

[\[5\]](https://www.bestwaresoda.com/wiki/cooling-airflow-checks/#editorial-source-5) [\[6\]](https://www.bestwaresoda.com/wiki/cooling-airflow-checks/#editorial-source-6) [\[7\]](https://www.bestwaresoda.com/wiki/cooling-airflow-checks/#editorial-source-7) [\[8\]](https://www.bestwaresoda.com/wiki/cooling-airflow-checks/#editorial-source-8) [\[9\]](https://www.bestwaresoda.com/wiki/cooling-airflow-checks/#editorial-source-9)

### Sources for This Edition

1. [Bestware G1DS-110 — Integrated Under-Counter Dispenser](https://www.bestware-sparkling.com/Products/Commercial-Sparkling-Water-Dispensers/All-in-one/G1DS-110) · Features & Benefits, note before the specifications. Minimum base cabinet size for the integrated model, 425 × 500 × 630 mm (W × D × H).
2. [Bestware G1DS-123 — Split Under-Counter Dispenser Without RO](https://www.bestware-sparkling.com/Products/Commercial-Sparkling-Water-Dispensers/4-in-1/G1DS-123) · Product configuration and Features & Benefits note. Minimum base cabinet for the units, 810 × 500 × 630 mm (W × D × H). Separate chilling and heating specifications.
3. [Bestware G1DS-1023 — Split Under-Counter Dispenser With Standalone RO](https://www.bestware-sparkling.com/Products/Commercial-Sparkling-Water-Dispensers/4-in-1/G1DS-1023) · Product configuration and Features & Benefits note. Minimum base cabinet for the units, 990 × 500 × 630 mm (W × D × H).
4. [Bestware G1DS-110 / G1DS-1010 Installation Manual — Space and Fan Placement](https://www.bestwaresoda.com/assets/documents/g1ds-110-g1ds-1010-installation-manual-2026-v1.1-en.pdf#page=9) · 2026 V1.1, PDF 9, print 13–14. The right view labels the front fan as an inlet, while its own instructions identify the outlet. Compare the left panel arrows and PDF pages 7 and 10.
5. [Bestware G1DS-110 / G1DS-1010 Installation Manual — Door Vent Grilles](https://www.bestwaresoda.com/assets/documents/g1ds-110-g1ds-1010-installation-manual-2026-v1.1-en.pdf#page=10) · 2026 V1.1, PDF 10, print 15, ventilation grid installation step 2. Front air outlet, lower grille B and separate A/B door cutout and grille installation dimensions.
6. [Bestware G1DS-123 / G1DS-1023 Installation Manual — Equipment Clearance](https://www.bestwaresoda.com/assets/documents/g1ds-123-g1ds-1023-installation-manual-2026-v1.2-en.pdf#page=9) · 2026 V1.2, PDF 9, print 13–14. Chilling unit space 425 × 500 × 630 mm and 35 mm at each side intake. Separate heating unit drawing marks left power switch access. Standalone RO is separately drawn.
7. [Bestware G1DS-123 / G1DS-1023 Installation Manual — Chiller Outlet and Door Grilles](https://www.bestwaresoda.com/assets/documents/g1ds-123-g1ds-1023-installation-manual-2026-v1.2-en.pdf#page=10) · 2026 V1.2, PDF 10, print 15, ventilation grid installation steps 1–2. Front chilling-unit outlet and A/B door and grille drawings.
8. [Bestware G1DS-110 / G1DS-1010 User Manual — Cooling Faults](https://www.bestwaresoda.com/assets/documents/g1ds-110-g1ds-1010-installation-manual-2026-v1.1-en.pdf#page=7) · 2026 V1.1, PDF 7, print 09. E3, no-code cooling fault and the diagram labeling the side inlet and front outlet.
9. [Bestware G1DS-123 / G1DS-1023 User Manual — Chilling Unit Cooling Faults](https://www.bestwaresoda.com/assets/documents/g1ds-123-g1ds-1023-installation-manual-2026-v1.2-en.pdf#page=7) · 2026 V1.2, PDF 7, print 09. E3 and no-code cooling fault. Air blockage, limited heat escape and fan-fault escalation are troubleshooting guidance.
10. [OpenStax College Physics 2e — Heat Pumps and Refrigerators](https://openstax.org/books/college-physics-2e/pages/15-5-applications-of-thermodynamics-heat-pumps-and-refrigerators) · §15.5, Air Conditioners and Refrigerators. The refrigeration process transfers heat to the surroundings. This source supplies the physical principle.
11. [ASHRAE Handbook — Duct Design, Louvers](https://handbook.ashrae.org/Handbooks/F25/IP/F25_Ch21/F25_Ch21_ip.aspx) · Chapter 21, Louvers. Blade geometry can alter free area and pressure drop. The building-HVAC sizing values in the chapter are outside this cabinet installation.

### Continue With These Decisions

- [G1DS-110](https://www.bestwaresoda.com/systems/g1ds-110/)
  
  Check the G1DS-110 dimensions and open the one-piece unit’s installation drawing.
- [G1DS-123](https://www.bestwaresoda.com/systems/g1ds-123/)
  
  Use the split-model specifications for the whole installation, then check the chiller and heater positions separately.

### Continue Exploring

Related to this article

[Technology & Design 4 min read Updated 2026-11-25 How to Size a Laboratory Faucet Spout Check where the water lands, how much room the tallest vessel needs and whether the operator can move it without hitting the faucet. Read article](https://www.bestwaresoda.com/wiki/choose-laboratory-faucet-spout-reach/)

Related to this article

[Technology & Design 4 min read Updated 2026-11-25 A Commercial Sparkling Water Buying Checklist Give every bidder the same serving schedule, cabinet drawing and sign-off test. Then compare the price for putting the system to work. Read article](https://www.bestwaresoda.com/wiki/commercial-sparkling-water-purchasing-checklist/)

Related to this article

[Technology & Design 5 min read Updated 2026-11-24 How to Plan Gym Bottle-Filling Stations Around Class Changeovers Count the people who arrive together, then test how long their bottles take to fill when both stations are in use. Read article](https://www.bestwaresoda.com/wiki/plan-fitness-venue-water-points/)

Related to this article