# How to Compare Water Dispenser Noise

Source: https://www.bestwaresoda.com/wiki/comparing-dispenser-noise/
Language: en-US

[Back to Water Wiki](https://www.bestwaresoda.com/wiki/)

Technology & Design

## How to Compare Water Dispenser Noise

Compare the same sound measurement in the same operating state, then listen at the nearest desk or table while the installed dispenser works.

Revised 2026-11-25

Two water units connected by tubing to an instrumented test bench

On this page

[Find out What the Decibel Figure Measures](https://www.bestwaresoda.com/wiki/comparing-dispenser-noise/#section-1) [Listen Past the First Pour](https://www.bestwaresoda.com/wiki/comparing-dispenser-noise/#section-2) [Set Up the Cabinet as It Will Be Used](https://www.bestwaresoda.com/wiki/comparing-dispenser-noise/#section-3) [Agree the Listening Positions Before the Test](https://www.bestwaresoda.com/wiki/comparing-dispenser-noise/#section-4)

### Find out What the Decibel Figure Measures

If a dispenser will sit beside a quiet desk, take the installed comparison there. Start the shortlist by asking suppliers for the same measurement. Sound power level describes sound radiated by the machine in a stated operating condition. Sound pressure level is a reading at a position, where distance, reflections and other sounds matter. Either can be reported in dB(A), which tells you the frequencies have been A-weighted. Ask which quantity it is, how it was measured and which parts of the machine were running.

For a sound pressure figure, request the microphone distance, height and position relative to the product, plus the background and measurement duration. Sound power figures can help compare sources tested with the same method and operating states. For what a guest hears, put the microphone where a guest actually sits. A different distance or a reflective counter can change what arrives there.

[\[1\]](https://www.bestwaresoda.com/wiki/comparing-dispenser-noise/#editorial-source-1) [\[3\]](https://www.bestwaresoda.com/wiki/comparing-dispenser-noise/#editorial-source-3)

### Listen Past the First Pour

A refrigerator experiment helps explain why it matters to hear the whole cycle. In a hemi-anechoic chamber, researchers placed a microphone roughly 1 m from the door and 1.5 m above the floor. Among the five units selected for that analysis, refrigerator 5 measured 17.2 dB(A) at normal compressor speed and 30.9 dB(A) at maximum. Refrigerator 2 measured 18.2 and 20.6 dB(A). These are average A-weighted sound pressure levels in the authors’ Table 2. The unit that was quieter at normal speed was louder at maximum.

On a dispenser, give steady cooling, a dispensing run and the recovery after it separate entries. Observe any compressor or pump starts that occur during the run. If you can only tell that a buzz began just after the pour, write down the timing and leave identification of the source to a follow-up. A repeated click might matter to a person on the phone even if it barely moves the average for the shift.

[\[2\]](https://www.bestwaresoda.com/wiki/comparing-dispenser-noise/#editorial-source-2) [\[3\]](https://www.bestwaresoda.com/wiki/comparing-dispenser-noise/#editorial-source-3)

### Set Up the Cabinet as It Will Be Used

For one undercounter layout, Bestware’s G1DS-123 installation drawing shows 35 mm at each side air intake on the chilling unit. Its door drawing aligns the grille with that unit’s exhaust. That tells the installer which cabinet conditions to keep during a noise trial. A sample run with the door off describes a different arrangement from normal operation with the finished, vented door closed.

If a grille or support is to be changed, ask the equipment supplier and installer to confirm cooling, clearances and service access before repeating the comparison. For a model noise figure, request a report for the exact unit, operating state and installation.

[Check the chiller cabinet and door grille before the trial](https://www.bestwaresoda.com/wiki/cooling-airflow-checks/)

[\[5\]](https://www.bestwaresoda.com/wiki/comparing-dispenser-noise/#editorial-source-5) [\[6\]](https://www.bestwaresoda.com/wiki/comparing-dispenser-noise/#editorial-source-6) [\[3\]](https://www.bestwaresoda.com/wiki/comparing-dispenser-noise/#editorial-source-3)

### Agree the Listening Positions Before the Test

Mark a near point and a real listening point such as the closest occupied desk. As an example, at 1 m from a finished cabinet face, suppose the 60-second A-weighted equivalent sound pressure level, LAeq, is 39 dB(A) with the dispenser silent and 41 dB(A) during a run. Keep those as the background and the combined room reading. The difference between the two is 2 dB. A cleaner comparison would repeat at the same point with a more stable and lower background before making a claim about the dispenser alone.

Put the measurement windows, operating sequence and acceptable sound at the listening point in the sign-off sheet. Agree how to record short events such as a starting click. Use an appropriate calibrated sound level meter and an agreed method for formal acceptance. NIOSH measurement guidance addresses occupational exposure. Agree a room comfort requirement for this job and keep the sound notes beside the actual pours and recovery times.

[Use the same run to check pours and recovery](https://www.bestwaresoda.com/wiki/plan-water-equipment-pilot-acceptance/)

[\[1\]](https://www.bestwaresoda.com/wiki/comparing-dispenser-noise/#editorial-source-1) [\[4\]](https://www.bestwaresoda.com/wiki/comparing-dispenser-noise/#editorial-source-4) [\[3\]](https://www.bestwaresoda.com/wiki/comparing-dispenser-noise/#editorial-source-3) [\[7\]](https://www.bestwaresoda.com/wiki/comparing-dispenser-noise/#editorial-source-7)

### Sources for This Edition

1. [Environment Agency · Best Available Techniques for Control of Noise & Vibration](https://assets.publishing.service.gov.uk/government/uploads/system/uploads/attachment_data/file/290397/sp4-079-tr-1-e-e.pdf) · P4-079/TR/1 (November 2001), PDF page 40, printed page 35, Appendix A. Sound power and sound pressure levels, A-frequency-weighting, time-equivalent level, maximum and residual noise.
2. Kosowski, Atamer & Altinsoy · A Study on Sound Level Differences in Working Modes of a Refrigerator With an Inverter Compressor · Forum Acusticum Euronoise 2025, DOI 10.61782/fa.2025.0040, PDF p. 3 (printed 3339), §4.2 and p. 4 (3340), §4.4 Tables 2–3. Two of five selected refrigerators; front microphone in a hemi-anechoic chamber, about 1 m from the door and 1.5 m above the floor. Device 5: 17.2 and 30.9 dB(A) SPL, device 2: 18.2 and 20.6 dB(A) SPL, normal and maximum compressor speed. These are pressure values from Table 2.
3. Bestware · Illustrative Installed Comparison Record · Hypothetical listening positions and matched 60-second LAeq windows, as an illustration only. Sample front point: 1 m from the finished cabinet face. 39 dB(A) with the dispenser silent and 41 dB(A) for the total sound during the observed run; 2 dB is the difference between readings, not a source level.
4. [NIOSH · Understand Noise Exposure](https://www.cdc.gov/niosh/noise/prevent/understand.html) · October 28, 2026, sound level meter guidance and dosimeter distinction. Occupational measurement context, separate from the job’s room comfort requirement.
5. [Bestware · G1DS-123 / G1DS-1023 Installation Manual V1.2](https://www.bestwaresoda.com/assets/documents/g1ds-123-g1ds-1023-installation-manual-2026-v1.2-en.pdf) · G1DS-123 example. PDF p. 9, printed p. 13, chilling-unit placement drawing with 35 mm side inlet gaps; PDF p. 10, printed p. 15, aligns the cabinet door grid opening to the chilling-unit air outlet. Installation dimensions only.
6. [Bestware Wiki · Cabinet Airflow](https://www.bestwaresoda.com/wiki/cooling-airflow-checks/) · Confirm the door grille, clearances and a serving test with the cabinet closed.
7. [Bestware Wiki · Pilot Acceptance](https://www.bestwaresoda.com/wiki/plan-water-equipment-pilot-acceptance/) · Observe the first pour, peak orders and recovery in a defined acceptance run.

### Continue With These Decisions

- [How to Plan and Check Airflow in a Water Chiller Cabinet](https://www.bestwaresoda.com/wiki/cooling-airflow-checks/)
  
  Check the chiller cabinet and door grille before the trial
- [How to Test a Commercial Water Dispenser Before You Accept It](https://www.bestwaresoda.com/wiki/plan-water-equipment-pilot-acceptance/)
  
  Use the same run to check pours and recovery

### Continue Exploring

Related to this article

[Technology & Design 3 min read Updated 2026-11-25 Home Soda Maker or Commercial Dispenser? Count the cold bottles you can start with and the glasses you can hand over in the busiest few minutes. Then run the same orders a second time. Read article](https://www.bestwaresoda.com/wiki/commercial-systems-and-home-soda-makers/)

Related to this article

[Technology & Design 3 min read Updated 2026-11-25 When to Trust Connected Water Dispenser Data Check one dashboard number against the water at the tap. Then follow a service alert until the work is done. Read article](https://www.bestwaresoda.com/wiki/connected-dispenser-operating-data/)

Related to this article

[Technology & Design 4 min read Updated 2026-11-24 How to Match a Sparkling Water Tap to Your Bottles and Glasses Bring your tallest bottle, check the fitted tap and time a mixed restaurant order from the first empty vessel to the last one handed over. Read article](https://www.bestwaresoda.com/wiki/matching-dispensing-flow-and-containers/)

Related to this article