# How to Choose Water Dispenser Controls

Source: https://www.bestwaresoda.com/wiki/choosing-dispensing-controls/
Language: en-US

[Back to Water Wiki](https://www.bestwaresoda.com/wiki/)

Technology & Design

## How to Choose Water Dispenser Controls

Try a small top-up and a full carafe before choosing a lever, button or sensor. Check how each pour starts, what happens when you stop it early and whether a new user can tell.

Revised 2026-11-25

Circular dispenser control with a zero-second display and a Press to stop message

On this page

[Make the Stop Action Part of the Spec](https://www.bestwaresoda.com/wiki/choosing-dispensing-controls/#section-1) [Read the Feedback While the Water Is Running](https://www.bestwaresoda.com/wiki/choosing-dispensing-controls/#section-2) [Try a Short Top-Up and a Long Pour](https://www.bestwaresoda.com/wiki/choosing-dispensing-controls/#section-3) [Watch a First-Time User Find the Right Control](https://www.bestwaresoda.com/wiki/choosing-dispensing-controls/#section-4) [Leave the Next Shift the Setting You Tested](https://www.bestwaresoda.com/wiki/choosing-dispensing-controls/#section-5)

### Make the Stop Action Part of the Spec

At a restaurant water station, a server may need a splash to finish a partly filled glass. The next person wants a carafe they can carry to the table. Try both jobs. A control that starts quickly is useful only if the person can also stop when the water reaches the right line.

Write down the trigger and the stop for each option you’re offered. A momentary lever or button opens the water while held and closes when released. Another control may start on a press and need a second press to stop. A timed pour can stop when its timer expires. Ask how to interrupt it. At a sensor station, find out whether you move a hand to toggle the flow or place a bottle where the sensor can see it.

[\[5\]](https://www.bestwaresoda.com/wiki/choosing-dispensing-controls/#editorial-source-5) [\[1\]](https://www.bestwaresoda.com/wiki/choosing-dispensing-controls/#editorial-source-1) [\[3\]](https://www.bestwaresoda.com/wiki/choosing-dispensing-controls/#editorial-source-3)

### Read the Feedback While the Water Is Running

In one human-use analysis posted by MIT’s product design course, the automatic bottle station started on seeing a bottle and stopped when the bottle was removed. The manual station in the same account stopped on release of the button. On your sample, try interrupting the pour halfway through. Watch whether the sensor continues to see the vessel when it is raised or tilted.

The 2026 V1.2 Bestware G1DS-123 / G1DS-1023 manual gives a different example. Rotate to chilled, sparkling or ambient water, then press the center to start. The display shows a countdown and tells you to press to stop. Each mode has its own time setting between 1 and 60 seconds. If that is the panel being quoted, have the supplier show the timer ending on its own and then repeat the pour with an early stop.

[\[1\]](https://www.bestwaresoda.com/wiki/choosing-dispensing-controls/#editorial-source-1) [\[3\]](https://www.bestwaresoda.com/wiki/choosing-dispensing-controls/#editorial-source-3)

### Try a Short Top-Up and a Long Pour

For a comparison, mark two fill lines. On the small glass, put its target line 60 mL above the amount already in it. On the carafe, mark a 750 mL service fill that still leaves room to carry it. These are example tasks. Use cold or ambient water, each site’s normal vessels, and enough tray space to catch a spill. For a hand control, set the vessel down before giving the start command. At a station that detects the vessel, find the position where it is meant to start. Check that moving past the station or bringing another vessel nearby does not trigger an unintended pour. Stop the small glass early, then see whether the carafe can reach its line in an uninterrupted run.

Record first-try starts, any unwanted start, the time it takes for water to begin and end after the relevant action, and the final volume after the drops settle. For instance, a hypothetical flow of 500 mL in 25 seconds averages 20 mL per second. If it stayed at that rate for half a second after the stop action, that would add about 10 mL. For a stop with the vessel left in place, use a marked test vessel and compare the levels at the stop action and after the drops settle. If removing the vessel stops the water, check what still falls into the tray. On a timed unit, record delivered volume for several complete runs too.

[Measure how much water the selected setting actually delivers](https://www.bestwaresoda.com/wiki/measured-dispensing-for-consistent-portions/)

[\[5\]](https://www.bestwaresoda.com/wiki/choosing-dispensing-controls/#editorial-source-5) [\[6\]](https://www.bestwaresoda.com/wiki/choosing-dispensing-controls/#editorial-source-6)

### Watch a First-Time User Find the Right Control

In a 2022 study, Shen and colleagues observed 20 people with experience using drinking equipment test one household dispenser. The researchers logged 18 wrong-button actions across the two sighted groups and three in the visually impaired group. The paper explains that the decoration could be mistaken for the dispensing button. Those events belong to that device and test. For your counter, ask someone unfamiliar with the fixture to show where they think the water starts and stops before you explain it.

Check the view from a seated approach and with the tall vessel in place. Try the controls in the fixtures and lighting that customers will actually encounter. If U.S. ADA rules apply to this installation, check the applicable approach, reach and operable-parts criteria separately with the design team.

[\[2\]](https://www.bestwaresoda.com/wiki/choosing-dispensing-controls/#editorial-source-2) [\[5\]](https://www.bestwaresoda.com/wiki/choosing-dispensing-controls/#editorial-source-5) [\[4\]](https://www.bestwaresoda.com/wiki/choosing-dispensing-controls/#editorial-source-4)

### Leave the Next Shift the Setting You Tested

Write down the fixture and panel revision, each control’s start and stop, tested vessel heights and fill lines, and which approved alternative is available if the unit is out of service. Assign cleaning for the actual outlet and tray. Repeat the short and long pours after installation or after a part or setting changes the way the water starts or stops.

Give hot water its own commissioning plan. Staff can rehearse the location of the controls with the water off, then have qualified people verify the installed hot-water mode under the agreed procedure while the point is closed to guests.

[Use the separate hot-water control acceptance procedure](https://www.bestwaresoda.com/wiki/test-table-side-hot-water-controls/)

[\[5\]](https://www.bestwaresoda.com/wiki/choosing-dispensing-controls/#editorial-source-5) [\[3\]](https://www.bestwaresoda.com/wiki/choosing-dispensing-controls/#editorial-source-3) [\[7\]](https://www.bestwaresoda.com/wiki/choosing-dispensing-controls/#editorial-source-7)

### Sources for This Edition

1. [MIT 2.744 · Human Use Analysis of a Water Bottle Filling Station](https://web.mit.edu/2.744/studentSubmissions/humanUseAnalysis/khn/experience.html) · User Experience, the automatic and manual station examples. One dispenses while the sensor sees the bottle and stops when it is removed. Another dispenses while the button is held and stops on release.
2. [Shen et al. · Study on the Design of a Water Dispenser for Visually Impaired Families (2022)](https://mdpi-res.com/d_attachment/sustainability/sustainability-14-02081/article_deploy/sustainability-14-02081.pdf) · DOI 10.3390/su14042081, PDF pp. 7–8, §3.3 and Table 3. Twenty experienced participants tried one household dispenser. In the wrong-button row, the two sighted groups made 10 and 8 errors, and the visually impaired group made 3. These are counted error events over two test rounds.
3. [Bestware · G1DS-123 / G1DS-1023 Installation Manual, 2026 V1.2](https://www.bestwaresoda.com/assets/documents/g1ds-123-g1ds-1023-installation-manual-2026-v1.2-en.pdf) · PDF p. 3, printed pp. 01–02. Chilled, sparkling and ambient modes show selection by rotating, center press to start, countdown and Press to stop. The time-setting diagram gives a separate setting per mode, from 1 to 60 seconds.
4. [U.S. Access Board · ADA Guide, Chapter 3 Operable Parts](https://www.access-board.gov/ada/guides/chapter-3-operable-parts/) · Operation \[§309.4\] and Clear Floor Space \[§309.2\]. Applied to the operable parts and installations that are within the standard’s scope.
5. Bestware Editorial · Illustrative Short Top-up and Carafe Test · Cold or ambient water exercises only. Mark a bottle or carafe and use the normal tray. Test the start, an early stop and natural completion if available. Separate a full timed fill from residual water collected after an early stop; no equipment output claimed.
6. [Bestware Wiki · Measured Dispensing for Consistent Portions](https://www.bestwaresoda.com/wiki/measured-dispensing-for-consistent-portions/) · Check actual cup delivery and repeatability rather than treating a timer setting as volume.
7. [Bestware Wiki · Test Table-side Hot Water Controls](https://www.bestwaresoda.com/wiki/test-table-side-hot-water-controls/) · Separate supervised hot-water commissioning and required vessel checks.

### Continue With These Decisions

- [How to Check a Preset Pour for Consistent Portions](https://www.bestwaresoda.com/wiki/measured-dispensing-for-consistent-portions/)
  
  Measure how much water the selected setting actually delivers
- [How to Test a Table-Side Hot-Water Control](https://www.bestwaresoda.com/wiki/test-table-side-hot-water-controls/)
  
  Use the separate hot-water control acceptance procedure

### Continue Exploring

Related to this article

[Technology & Design 4 min read Updated 2026-11-24 How to Test a Metering Faucet Before You Approve It Time one press, collect the whole discharge and try the installed basin as someone would use it. Keep the accessibility check and the product water-use report with that same configuration. Read article](https://www.bestwaresoda.com/wiki/accept-metering-faucet-cycles/)

Related to this article

[Technology & Design 4 min read Updated 2026-11-24 How to Test a Commercial Pre-Rinse Spray Valve Before You Accept It Use a real rack of dishes. Count the extra passes, read the meter and check that the hand spray closes when the operator lets go. Read article](https://www.bestwaresoda.com/wiki/accept-pre-rinse-spray-valves/)

Related to this article

[Technology & Design 4 min read Updated 2026-11-25 How to Test a Sensor Faucet in the Installed Basin Pilot a real pair of wash stations, count missed and unintended starts separately and keep the settings that produced the result. Read article](https://www.bestwaresoda.com/wiki/accept-sensor-faucets-in-the-installed-basin/)

Related to this article