# Countertop, Undercounter or Freestanding Water Dispenser?

Source: https://www.bestwaresoda.com/wiki/choosing-a-water-dispenser-format/
Language: en-US

[Back to Water Wiki](https://www.bestwaresoda.com/wiki/)

Technology & Design

## Countertop, Undercounter or Freestanding Water Dispenser?

Compare the space people use, the equipment you are actually ordering and the route a technician will need to service it.

Revised 2026-11-24

A curved metal dispensing tap and clear glass on a counter beside a tray of cups

On this page

[Start With the Space You Can Give Up](https://www.bestwaresoda.com/wiki/choosing-a-water-dispenser-format/#section-1) [Draw the Whole Station, Including the Parts You Cannot See](https://www.bestwaresoda.com/wiki/choosing-a-water-dispenser-format/#section-2) [Check What the Countertop Fabricator Will Actually Cut](https://www.bestwaresoda.com/wiki/choosing-a-water-dispenser-format/#section-3) [Sign off With the Door and the Station in Use](https://www.bestwaresoda.com/wiki/choosing-a-water-dispenser-format/#section-4)

### Start With the Space You Can Give Up

Keep a countertop dispenser on the shortlist when a stable work surface is available and there is enough room to fill the largest vessel you use. An undercounter system makes sense when work surface is scarce and you can reserve a ventilated cabinet with a workable service opening. A freestanding station is worth drawing when cabinet space is already spoken for and the floor layout can accommodate both the machine and people waiting for water.

Stand where customers or staff will fill a bottle, then stand where a technician will have to work. Mark both positions and the route people take past them. A recess that looks right on the plan may put a waiting guest in the way of a server carrying a tray. Include the space needed to move the machine into place and to open its service panels.

[\[6\]](https://www.bestwaresoda.com/wiki/choosing-a-water-dispenser-format/#editorial-source-6) [\[5\]](https://www.bestwaresoda.com/wiki/choosing-a-water-dispenser-format/#editorial-source-5)

### Draw the Whole Station, Including the Parts You Cannot See

For a countertop unit, note the filled operating weight, supporting surface and clearance above the outlet or fill lid. Put any separate filter or gas cylinder on the same drawing. For a freestanding unit, check the model's footprint, leveling or anchoring instructions and utility entry. Draw the service side with the enclosure open. A lower bottle compartment or a filter behind a cover needs its own loading or removal route.

For an undercounter setup, write the exact configuration on the cabinet plan. Bestware lists minimum base-cabinet dimensions of 425 × 500 × 630 mm for the integrated G1DS-110, 810 × 500 × 630 mm for the G1DS-123 with separate chilling and heating units, and 990 × 500 × 630 mm for the G1DS-1023 configuration that includes standalone reverse osmosis (RO). The order is width × depth × height. If the G1DS-123 manual is already open at the chilling-unit drawing, its 425 mm width is for that placement alone.

Open the doors on the drawing and mark the hoses, grille, shutoff and direction the filter cartridge or module must come out. For the RO variant, plot its tubing and the drain route shown in the applicable manual. Check the finished clear width through the opening after hinges and face frame are fitted. If the supplier changes the RO module or the installer moves a partition, rerun the fit and access checks.

[See how to check cabinet airflow with the door closed](https://www.bestwaresoda.com/wiki/cooling-airflow-checks/)

[\[1\]](https://www.bestwaresoda.com/wiki/choosing-a-water-dispenser-format/#editorial-source-1) [\[2\]](https://www.bestwaresoda.com/wiki/choosing-a-water-dispenser-format/#editorial-source-2) [\[3\]](https://www.bestwaresoda.com/wiki/choosing-a-water-dispenser-format/#editorial-source-3) [\[5\]](https://www.bestwaresoda.com/wiki/choosing-a-water-dispenser-format/#editorial-source-5) [\[7\]](https://www.bestwaresoda.com/wiki/choosing-a-water-dispenser-format/#editorial-source-7)

### Check What the Countertop Fabricator Will Actually Cut

Put the real bottle or pitcher under the outlet on a marked-up counter. Watch where the hand goes, where drips land and whether a tray can slide out past the neighboring work. A template should show each opening, the material thickness where it is clamped and the space below to reach its nut and plumbing.

Suppose a stone top measures 38 mm at both parts. The Bestware G1DS-110 manual shows a maximum of 40 mm for the tap and 36 mm for the drip tray. The thickness meets the tap limit and exceeds the tray limit. Let the fabricator and installer resolve the tray mounting on the approved drawing before drilling. Where U.S. accessibility provisions apply, have the project team confirm the type of fixture, its approach and controls separately.

[\[4\]](https://www.bestwaresoda.com/wiki/choosing-a-water-dispenser-format/#editorial-source-4) [\[6\]](https://www.bestwaresoda.com/wiki/choosing-a-water-dispenser-format/#editorial-source-6)

### Sign off With the Door and the Station in Use

Give the installer one drawing showing the purchased configuration, connection routes and approved cut-outs. At handover, fill the vessel you mocked up and run the agreed service cycle with doors, shelves and trims in their finished positions. Have the installer point out the isolation valve and demonstrate the planned route to replace the filter or remove a module using the model's service procedure. Record the equipment and drawing revision after checking. The next order can then be compared against the installation that actually fits.

[\[4\]](https://www.bestwaresoda.com/wiki/choosing-a-water-dispenser-format/#editorial-source-4) [\[5\]](https://www.bestwaresoda.com/wiki/choosing-a-water-dispenser-format/#editorial-source-5) [\[7\]](https://www.bestwaresoda.com/wiki/choosing-a-water-dispenser-format/#editorial-source-7)

### Sources for This Edition

1. [Bestware G1DS-110 Product Specifications](https://www.bestware-sparkling.com/Products/Commercial-Sparkling-Water-Dispensers/All-in-one/G1DS-110) · Features & Benefits, minimum base cabinet for this integrated configuration, 425 × 500 × 630 mm (W × D × H).
2. [Bestware G1DS-123 Product Specifications](https://www.bestware-sparkling.com/Products/Commercial-Sparkling-Water-Dispensers/4-in-1/G1DS-123) · Features & Benefits and configuration, separate chilling and heating units without standalone RO, minimum base cabinet 810 × 500 × 630 mm (W × D × H).
3. [Bestware G1DS-1023 Product Specifications](https://www.bestware-sparkling.com/Products/Commercial-Sparkling-Water-Dispensers/4-in-1/G1DS-1023) · Features & Benefits and configuration, split units and standalone RO, minimum base cabinet 990 × 500 × 630 mm (W × D × H).
4. [Bestware G1DS-110 / G1DS-1010 Installation Manual](https://www.bestwaresoda.com/assets/documents/g1ds-110-g1ds-1010-installation-manual-2026-v1.1-en.pdf#page=10) · 2026 V1.1, PDF page 10, printed pages 15–16. Ventilation grille, countertop cut-outs and separate maximum thicknesses for drip tray (36 mm) and tap (40 mm).
5. [Bestware G1DS-123 / G1DS-1023 Installation Manual](https://www.bestwaresoda.com/assets/documents/g1ds-123-g1ds-1023-installation-manual-2026-v1.2-en.pdf#page=9) · 2026 V1.2, PDF 9, printed pages 13–14. Chilling unit, heating unit and standalone RO placement diagrams. Chilling-unit space is 425 × 500 × 630 mm. PDF 10 shows the door grille; PDF 10–11 give drip tray and tap installation.
6. [U.S. Access Board — Guide to Drinking Fountains](https://www.access-board.gov/ada/guides/chapter-6-drinking-fountains/) · Application and Bottle Fillers guidance. In U.S. projects, confirm fixture classification and the applicable requirements for approach and access.
7. [Bestware — Cabinet Airflow and Cooling Checks](https://www.bestwaresoda.com/wiki/cooling-airflow-checks/) · Door grille and cabinet clearance guidance for the referenced G1DS configurations.

### Continue With These Decisions

- [G1DS-110](https://www.bestwaresoda.com/systems/g1ds-110/)
  
  Open the integrated model specifications and drawing.
- [G1DS-123](https://www.bestwaresoda.com/systems/g1ds-123/)
  
  Size the cabinet using the complete split configuration.

### Continue Exploring

Related to this article

[Technology & Design 4 min read Updated 2026-11-25 Mains-Fed, Bottle-Fed or Refillable? Choose How Water Reaches the Dispenser Use an approved building feed where it fits. A delivered bottle or a refillable tank can serve another room if someone can replenish it and it can cover the actual rush. Read article](https://www.bestwaresoda.com/wiki/mains-fed-and-bottle-fed-dispensers/)

Related to this article

[Technology & Design 4 min read Updated 2026-11-25 A Commercial Sparkling Water Buying Checklist Give every bidder the same serving schedule, cabinet drawing and sign-off test. Then compare the price for putting the system to work. Read article](https://www.bestwaresoda.com/wiki/commercial-sparkling-water-purchasing-checklist/)

Related to this article

[Technology & Design 4 min read Updated 2026-11-25 All-in-One or Split Water Dispenser? Compare the Installation Drawings Ask for one drawing that shows what sits under the counter, what connects to the tap and what each supplier will deliver. Then compare the two layouts on your own cabinet. Read article](https://www.bestwaresoda.com/wiki/integrated-and-modular-systems/)

Related to this article