# How to Size a Laboratory Faucet Spout

Source: https://www.bestwaresoda.com/wiki/choose-laboratory-faucet-spout-reach/
Language: en-US

[Back to Water Wiki](https://www.bestwaresoda.com/wiki/)

Technology & Design

## How to Size a Laboratory Faucet Spout

Check where the water lands, how much room the tallest vessel needs and whether the operator can move it without hitting the faucet.

Revised 2026-11-25

Bestware laboratory faucet drawing with 200 mm spout reach and 250 mm outlet height

On this page

[Mark Where You Need the Water](https://www.bestwaresoda.com/wiki/choose-laboratory-faucet-spout-reach/#section-1) [Compare the Two Heights on the Drawing](https://www.bestwaresoda.com/wiki/choose-laboratory-faucet-spout-reach/#section-2) [Work the Handle and, if It Swivels, Trace the Arc](https://www.bestwaresoda.com/wiki/choose-laboratory-faucet-spout-reach/#section-3) [Check the Deck Above and Below](https://www.bestwaresoda.com/wiki/choose-laboratory-faucet-spout-reach/#section-4) [Use the Actual Vessel at Handover](https://www.bestwaresoda.com/wiki/choose-laboratory-faucet-spout-reach/#section-5)

### Mark Where You Need the Water

Set your tallest regularly used vessel in the sink, on whatever will support it during filling. Mark where its mouth sits with a hand on it. On the plan, measure from the faucet’s mounting axis to that spot. Take the bowl’s inside width and front-to-back dimension as well. They show what happens if the vessel has to sit off center or behind a divider.

Spout reach is the horizontal distance from the mounting axis to the outlet center on the drawing. Outlet height is the vertical distance from the finished deck to the end of the outlet. Check the faucet’s overall height against the shelf or cabinet above, and use the outlet height when you calculate room for the vessel.

[\[1\]](https://www.bestwaresoda.com/wiki/choose-laboratory-faucet-spout-reach/#editorial-source-1) [\[2\]](https://www.bestwaresoda.com/wiki/choose-laboratory-faucet-spout-reach/#editorial-source-2)

### Compare the Two Heights on the Drawing

The Bestware catalog gives the rigid LABG16L-A and swivel LABSG16L-A aerator versions a 200 mm reach, a 250 mm outlet height and a 390 mm overall height. The corresponding TN versions with the serrated hose tip show the same reach and overall height, with the outlet ending at 228 mm above the deck. A quote that only lists 390 mm leaves out the dimension that decides whether the mouth can come under the outlet.

For a drawing check, suppose the mounting axis is 60 mm behind the inside back edge of a bowl that measures 400 mm from front to back. A 200 mm reach aimed straight into the bowl puts the outlet center 140 mm in from that edge. A 280 mm vessel standing on a rack 50 mm below the deck puts its mouth 230 mm above the deck. That leaves 20 mm below the aerator on paper. The serrated tip would end 2 mm below the mouth at that same position. Check whether another support position or another fixture works before cutting the counter.

[\[2\]](https://www.bestwaresoda.com/wiki/choose-laboratory-faucet-spout-reach/#editorial-source-2) [\[3\]](https://www.bestwaresoda.com/wiki/choose-laboratory-faucet-spout-reach/#editorial-source-3) [\[1\]](https://www.bestwaresoda.com/wiki/choose-laboratory-faucet-spout-reach/#editorial-source-1)

### Work the Handle and, if It Swivels, Trace the Arc

A fixed spout suits a marked fill position if the vessel can get in and out with room for both hands. With a swivel, lay out just the part of the arc the operator needs. Have someone try moving a tall empty vessel through the space and operating the handle at both ends of the useful swing. Check the backsplash, the divider and the next fixture, and try the controls from the position the operator will use.

For sinks dedicated to washing glassware, the EPA’s own facility manual calls for a high or telescoping outlet with a swing gooseneck to fit large pieces. A 2026 renovation tender at West Virginia University distinguishes its accessible station from the Fluids Lab in the fixture attachment. Put that same distinction on your plan if stations have different users or jobs.

[\[2\]](https://www.bestwaresoda.com/wiki/choose-laboratory-faucet-spout-reach/#editorial-source-2) [\[4\]](https://www.bestwaresoda.com/wiki/choose-laboratory-faucet-spout-reach/#editorial-source-4) [\[5\]](https://www.bestwaresoda.com/wiki/choose-laboratory-faucet-spout-reach/#editorial-source-5)

### Check the Deck Above and Below

On a replacement, open the cabinet and measure the finished deck where the mounting hardware clamps. The LABSG16L-A drawing marks a Ø21–23 mm hole and a maximum deck thickness of 42 mm. Check whether mounting hardware and supply connections can be reached from below, and whether the specified handle side leaves room to use the control. Give the installer a marked section with the mounting axis before a hole is drilled.

[Check the mounting hole and cabinet access on a replacement](https://www.bestwaresoda.com/wiki/replace-water-fixtures-in-existing-counters/)

[\[3\]](https://www.bestwaresoda.com/wiki/choose-laboratory-faucet-spout-reach/#editorial-source-3) [\[2\]](https://www.bestwaresoda.com/wiki/choose-laboratory-faucet-spout-reach/#editorial-source-2) [\[6\]](https://www.bestwaresoda.com/wiki/choose-laboratory-faucet-spout-reach/#editorial-source-6)

### Use the Actual Vessel at Handover

Once the installation is ready for service, give the installer the vessel type, where it sits and which outlet was ordered. Use clean water to check where the stream lands and whether the mouth can be moved in, filled and lifted out without touching the faucet. For a swivel, repeat at each intended working position. Record the installed fixture and tip, the useful positions and any item that still needs resolving.

[Record the installed outlet and remaining work at handover](https://www.bestwaresoda.com/wiki/water-system-installation-and-handover/)

[\[1\]](https://www.bestwaresoda.com/wiki/choose-laboratory-faucet-spout-reach/#editorial-source-1) [\[5\]](https://www.bestwaresoda.com/wiki/choose-laboratory-faucet-spout-reach/#editorial-source-5) [\[7\]](https://www.bestwaresoda.com/wiki/choose-laboratory-faucet-spout-reach/#editorial-source-7)

### Sources for This Edition

1. Bestware — Illustrative Laboratory Sink Fit Check · Hypothetical water station. Mounting axis 60 mm behind the inner rear rim of a 400 mm bowl; 280 mm vessel on a support 50 mm below the finished deck. Nominal drawing check, without measured fit or acceptance result.
2. [Bestware 2025 Catalog V1.0 — Laboratory Faucet Drawings](https://www.bestware-stainless.com/upload/filexk_catalogs/2025-Bestware-CatalogV1.0.pdf) · PDF p. 46, printed p. 77, LABG16L-A and LABSG16L-A aerator drawing; p. 47, printed p. 79, LABG16L-TN and LABSG16L-TN serrated-tip drawing. 200 mm projection and 390 mm overall height; 250 and 228 mm from deck to outlet respectively.
3. [Bestware — LABSG16L-A Laboratory Faucet](https://www.bestware-stainless.com/Products/Laboratory-Faucets/Single-spout/LABSG16L-A) · Model specifications and gallery drawing. Deck-mounted swivel, left-hand handle, Ø21–23 mm mounting hole. Gallery drawing: maximum deck thickness 42 mm.
4. [U.S. EPA Facilities Manual, Volume 2 — Water Fixtures and Fittings](https://www.epa.gov/system/files/documents/2023-12/epa-facilities-manual-vol-2-architecture-engineering-guidelines.pdf) · Revised December 15, 2023. PDF p. 83, printed p. 7-25, §7.7.3, Glassware Washing Sinks. High or telescoping outlet with a swing gooseneck for large glassware at EPA facilities.
5. West Virginia University — Mineral Resource Building Core Lab Renovation Phase II, RFB202690000695 · Tender released February 26, 2026. Attachment E, Plumbing Fixtures Information, separately annotates EQT ADA Station and Fluids Lab on fixture documents. Tender record.
6. [Bestware Wiki — Replacing Water Fixtures in Existing Counters](https://www.bestwaresoda.com/wiki/replace-water-fixtures-in-existing-counters/) · Check existing mounting holes, finished deck and below-counter access.
7. [Bestware Wiki — Water System Installation and Handover](https://www.bestwaresoda.com/wiki/water-system-installation-and-handover/) · Record fixture details, visible checks and open items at handover.

### Continue With These Decisions

- [Replacing a Commercial Tap? Measure the Existing Counter First](https://www.bestwaresoda.com/wiki/replace-water-fixtures-in-existing-counters/)
  
  Check the mounting hole and cabinet access on a replacement
- [Water Dispenser Installation and Handover: What to Sign Off](https://www.bestwaresoda.com/wiki/water-system-installation-and-handover/)
  
  Record the installed outlet and remaining work at handover

### Continue Exploring

Related to this article

[Technology & Design 4 min read Updated 2026-11-25 A Commercial Sparkling Water Buying Checklist Give every bidder the same serving schedule, cabinet drawing and sign-off test. Then compare the price for putting the system to work. Read article](https://www.bestwaresoda.com/wiki/commercial-sparkling-water-purchasing-checklist/)

Related to this article

[Technology & Design 4 min read Updated 2026-11-24 How to Plan and Check Airflow in a Water Chiller Cabinet Size the cabinet for the full order, line up the exhaust with the door grille and run the agreed serving test with the finished cabinet closed. Read article](https://www.bestwaresoda.com/wiki/cooling-airflow-checks/)

Related to this article

[Technology & Design 5 min read Updated 2026-11-24 How to Plan Gym Bottle-Filling Stations Around Class Changeovers Count the people who arrive together, then test how long their bottles take to fill when both stations are in use. Read article](https://www.bestwaresoda.com/wiki/plan-fitness-venue-water-points/)

Related to this article
