# How to Verify a Filter’s NSF Protocol 549 Claim for Glyphosate Reduction

Source: https://www.bestwaresoda.com/journal/nsf-p549-glyphosate-claims/
Language: en-US

[Back to Journal](https://www.bestwaresoda.com/journal/)

Water & Science

## How to Verify a Filter’s NSF Protocol 549 Claim for Glyphosate Reduction

NSF released a way to verify a specific filter claim on October 14, 2026. A purchase still comes down to the listed model, the cartridge in the quote, and what the certification actually covers.

Source date 2026-10-14 · Revised 2026-11-25

Sample bottles and vials of different sizes on a laboratory bench

On this page

[What NSF Released on October 14](https://www.bestwaresoda.com/journal/nsf-p549-glyphosate-claims/#section-1) [What a 53 or 58 Listing Tells You](https://www.bestwaresoda.com/journal/nsf-p549-glyphosate-claims/#section-2) [Look Up the System and the Replacement Cartridge](https://www.bestwaresoda.com/journal/nsf-p549-glyphosate-claims/#section-3) [Leave a Record the Next Buyer Can Use](https://www.bestwaresoda.com/journal/nsf-p549-glyphosate-claims/#section-4)

### What NSF Released on October 14

NSF launched Protocol 549 on October 14, 2026. NSF describes it as voluntary third-party certification for glyphosate reduction claims on point-of-use drinking water treatment products. NSF says a product tested to the protocol must bring glyphosate in the resulting water to 0.28 mg/L or less under the protocol’s test conditions. That figure describes a certification test outcome. The requirements for drinking water at a particular site still come from the rules that apply there.

The announcement names activated carbon and reverse osmosis as examples of possible treatment technologies. A buyer can now ask for a specific piece of evidence for either approach. Ask for the issuer’s record for glyphosate reduction on the product being offered. The announcement itself gives a test criterion. The product record tells you which model and configuration the issuer has verified.

[\[1\]](https://www.bestwaresoda.com/journal/nsf-p549-glyphosate-claims/#editorial-source-1) [\[3\]](https://www.bestwaresoda.com/journal/nsf-p549-glyphosate-claims/#editorial-source-3) [\[2\]](https://www.bestwaresoda.com/journal/nsf-p549-glyphosate-claims/#editorial-source-2)

### What a 53 or 58 Listing Tells You

NSF says P549 aligns with testing used for NSF/ANSI 53 and NSF/ANSI 58. Standard 53 covers specific health-related reduction claims, such as lead reduction when it appears in the product’s listing. Standard 58 covers point-of-use reverse osmosis systems and their applicable requirements and claims. The claim line matters with either standard. A 53 listing that names lead documents lead reduction for that configuration. A 58 listing identifies the reverse osmosis system and whatever claims are shown in its record. For glyphosate under P549, ask for that protocol and that claim together.

Read the certification mark as a clue to the issuer. A lab report can document a test on a sample, and a performance data sheet can describe how a product is expected to be used. For a bid that requires certification to P549, the current issuer record is the evidence to use when deciding if the model meets that requirement.

[\[1\]](https://www.bestwaresoda.com/journal/nsf-p549-glyphosate-claims/#editorial-source-1) [\[4\]](https://www.bestwaresoda.com/journal/nsf-p549-glyphosate-claims/#editorial-source-4) [\[7\]](https://www.bestwaresoda.com/journal/nsf-p549-glyphosate-claims/#editorial-source-7) [\[2\]](https://www.bestwaresoda.com/journal/nsf-p549-glyphosate-claims/#editorial-source-2)

### Look Up the System and the Replacement Cartridge

Start at NSF’s public Certified Products and Systems page for an NSF claim. Search the certification holder or trade name and then match the complete system model, including any suffix. Read the reduction claims and the specified replacement element. The older drinking water directory showed 53 and 58 in its standard selector on November 25, 2026. That form offered no dedicated P549 option on that date. A keyword search in the current directory can return a text match. Open the listing and check the protocol and the exact model before using it. If the record is hard to locate, ask for a current listing link or written confirmation of the model and scope from NSF’s Certification Records Department. Record a gap as unverified while you wait.

Suppose a café gets a quote for a Bestware dispenser and a separately supplied filter. The bid requires P549 evidence, but the attachment lists a filter under 53 for lead and the quote shows only the cartridge family. Keep the dispenser and filter on separate lines. Leave the glyphosate requirement open, and ask for the record identifying the exact filter system and approved cartridge. The lead entry can stay in the procurement file with its own scope.

[\[3\]](https://www.bestwaresoda.com/journal/nsf-p549-glyphosate-claims/#editorial-source-3) [\[5\]](https://www.bestwaresoda.com/journal/nsf-p549-glyphosate-claims/#editorial-source-5) [\[6\]](https://www.bestwaresoda.com/journal/nsf-p549-glyphosate-claims/#editorial-source-6) [\[7\]](https://www.bestwaresoda.com/journal/nsf-p549-glyphosate-claims/#editorial-source-7) [\[4\]](https://www.bestwaresoda.com/journal/nsf-p549-glyphosate-claims/#editorial-source-4)

### Leave a Record the Next Buyer Can Use

Once the scope is confirmed, keep the issuer, listing reference, verification date, full system and replacement part numbers, and the relevant revision of the performance data sheet with the quote. Copy rated flow, service capacity and replacement conditions when those fields are given for the approved configuration. Keep the units as published. The flow needed to keep a bar moving goes in the site specification, where it can be checked against the filter’s documented flow.

Use the same file when maintenance orders a replacement. If a supplier offers an alternate cartridge, compare its part number with the current certification record before it is accepted against the P549 requirement. That leaves the team a quick, repeatable check at the point where the equipment configuration actually changes.

[How to match a certificate to the model on the quote](https://www.bestwaresoda.com/wiki/read-certification-correctly/)

[\[5\]](https://www.bestwaresoda.com/journal/nsf-p549-glyphosate-claims/#editorial-source-5) [\[7\]](https://www.bestwaresoda.com/journal/nsf-p549-glyphosate-claims/#editorial-source-7) [\[8\]](https://www.bestwaresoda.com/journal/nsf-p549-glyphosate-claims/#editorial-source-8) [\[4\]](https://www.bestwaresoda.com/journal/nsf-p549-glyphosate-claims/#editorial-source-4)

### Sources for This Edition

1. NSF · Launches Protocol 549 for Glyphosate Reduction Claims · Original Announcement, October 14, 2026 · Original NSF announcement, October 14, 2026, introductory and final paragraphs. Introduces independent verification and states the 0.28 mg/L test criterion, alignment with 53 and 58, and possible treatment methods. The accessible October 16 reprint is listed separately.
2. [ASPE Pipeline · NSF Launches Protocol 549 for Glyphosate Reduction Claims](https://aspe.org/pipeline/nsf-launches-protocol-549-for-glyphosate-reduction-claims/) · Accessible October 16, 2026 reprint credited to NSF International. Closing paragraphs carry the 0.28 mg/L test result criterion, NSF/ANSI 53 and 58 alignment, and examples of activated carbon and reverse osmosis. The date on this copy is the reprint date.
3. NSF · Protocol 549 – Drinking Water Treatment Units, Glyphosate Reduction · Program Description · Original UK program description. Heading identifies treatment at the point of use. “What is NSF Protocol 549?” describes a voluntary third-party certification program for drinking water treatment products.
4. [U.S. EPA · WaterSense Guide to Selecting Water Treatment Systems](https://www.epa.gov/system/files/documents/2025-01/ws-products-home-water-treatment-guide_v2_508.pdf) · November 2024 edition. Table 2, printed PDF page 6, distinguishes NSF/ANSI 53 health effects and 58 reverse osmosis. Page 8 describes checking the exact target contaminant against the performance data sheet and certifier listing.
5. [NSF · Certified Products and Systems · Current Public Search](https://listings.nsf.org/certified-products-systems) · Issuer directory. Search by holder or exact model and open its complete listing to read the standard, claim and covered parts. A general keyword hit is not proof of a P549 claim.
6. [NSF · Drinking Water Treatment Units · Legacy Search](https://info.nsf.org/Certified/DWTU/) · November 25, 2026 read of the legacy Product Standard selector showed NSF 53 and 58 without a distinct P549 option. This observation is limited to the legacy form on that date.
7. NSF · Product Label and Literature Claims · Data Plate and Performance Data Sheet · Original guidance sections Product Data Plate and Performance Data Sheet. Packaging, nameplate, manuals and data sheets serve different documentation roles. For an open guide to checking the data sheet and issuer listing, see the WaterSense guide.
8. [Bestware — Read Certification Correctly](https://www.bestwaresoda.com/wiki/read-certification-correctly/) · Match model name, certification scope, and equipment supplied

### Continue With These Decisions

- [Does a Point-of-Use Water Filter Need NSF 61?](https://www.bestwaresoda.com/wiki/nsf-point-of-use-scope/)
  
  Read the model and claim on a real NSF 42, 53 or 58 listing.
- [How to Check a Water Equipment Certificate Before You Buy](https://www.bestwaresoda.com/wiki/read-certification-correctly/)
  
  Check the method and what to record.
- [How to Size Multistage Water Filtration for a Café](https://www.bestwaresoda.com/wiki/planning-multistage-filtration/)
  
  Check the method and what to record.

### Continue Exploring

Related to this article

[Water & Science 3 min read Source date 2026-10-15 What the 2026 Studies Found About Chloronitramide in Drinking Water Scientists have measured chloronitramide in small groups of tap-water samples and reported effects in cultured cells. The studies answer different questions. Here is what they mean when you read a water report or a filter claim. Read article](https://www.bestwaresoda.com/journal/chloronitramide-drinking-water-research-2026/)

Related to this article

[Water & Science 3 min read Updated 2026-11-25 How to Compare Microfiltration, Ultrafiltration, Nanofiltration and Reverse Osmosis Start with what the water needs to lose or retain. Then compare the production of the complete system under the same conditions, and check what reaches the tap. Read article](https://www.bestwaresoda.com/wiki/comparing-membrane-filtration/)

Related to this article

[Water & Science 3 min read Updated 2026-11-25 Does a Point-of-Use Water Filter Need NSF 61? Read the actual NSF 42, 53 and 58 claims before approving a filter and its replacement cartridge. Check separately ordered taps and valves against the project requirements. Read article](https://www.bestwaresoda.com/wiki/nsf-point-of-use-scope/)

Related to this article